-80 °C pontos do equipamento de funcionamento do fabricante do frigorífico
When the user chooses the -80 °C refrigerator, it is definitely necessary to have a reliable quality. Wuxi Guanya (LNEYA)-80 °C refrigerator should pay attention to its operation details during operation to avoid equipment failure caused by improper operation.
The following items should be mastered during use. Please check if the -80 °C refrigerator is damaged during installation, and choose the right place for installation and future maintenance. The site where the unit is installed must be the floor, mounting mat or foundation with a level of 6.4 mm and can withstand the operating weight of the unit. – It should be placed in a machine room with a room temperature of 4.4-43.3 °C. There should be enough space around and above the unit for routine maintenance work. A pipe space for cleaning the condenser tube bundle should be left at one end of the device, or a door hole or other suitable hole can be used.
Select the water pipe of the appropriate pipe diameter, the cooling system and the cold water system of the -80 °C refrigerator unit during high power operation, and connect them correctly. For normal applications, the water flow rate through the evaporator and condenser is between 1.0 and 3.6 m/s.
Under any load, the water flow rate should be stable. All chilled water and cooling water pipes should be designed and installed according to the conventional method. The chilled water pump should be located on the inlet pipe of the unit to ensure the positive pressure and flow in the unit. The piping should be provided with a damping tube to ensure proper flexibility and to prevent the evaporator water from being drained when the pump is shut down. The piping should have a solid support independent of the -80 °C refrigeration unit to prevent stress from being applied to the refrigeration unit components. The hangers are set up to facilitate pipe alignment.
-80 °C refrigerator manufacturers will provide corresponding instructions when the equipment is shipped from the factory, users need to read and operate carefully when using.
Recomendações relacionadas
-
Sistema de controlo integrado do dispositivo de ciclo de alta e baixa temperatura Dispositivos de utilização da série ZLF
1652With the development of society, the chemical industry has been further developed, and the temperature system control of the reactor has been strengthened, so as to ensure that the monitoring environment is in a good state, to ensure that the temp...
Ver detalhes -
A que é que devemos prestar atenção quando armazenamos o fluido frigorigéneo do refrigerador? Quais são as condições de aceitação
1541O refrigerante é uma substância essencial para fazer com que o refrigerador tenha efeito de refrigeração, o que apresenta grandes riscos potenciais de segurança no processo de utilização. O refrigerante, também chamado de refrigerante, transportador de refrigerante e semente de neve, é utilizado em diferentes equipamentos...
Ver detalhes -
Analysis of the reasons for non-refrigeration of cryogenic refrigeration equipment
1710Ultra-low temperature refrigeration equipment is mainly used in industrial cold processing. Unlike some manufacturers of ultra-low temperature refrigeration equipment, LNEYA ultra-low temperature refrigeration equipment uses environmentally friend...
Ver detalhes -
Que sectores são aplicáveis aos ensaios de dispositivos de semicondutores?
1776Semiconductor device testing is used in many semiconductor industries. So, how much do you know about semiconductors and conductors for semiconductor device testing? The properties of this substance are still recommended to the user. In general, s...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor