Princípio de refrigeração do sistema de refrigeração de glicol LNEYA
Glycol Chiller System SUNDI -10℃ ~ 200℃, as we can tell from its name, it is to use Glycol as the refrigeration agent for the chiller.
In the all air environment, because of the low temperature in the outdoors, it is impossible to use a cooling tower to supply the inner area directly with the cold air-conditioner. In addition, the cold air in the outdoors could be used directly as refrigerator source,with glycol as refrigerant, it can introduce the natural cold air into the inner area and supply cold air-conditioner. If we need to heat the outer area and provide cooling for the inner area, we can turn off the chiller and still use the boiler or the urban hot water as the heat source to heat the outer area.
Install plate heat exchanger in the outdoor, and the outdoor cold air is introduced into the plate heat exchanger by the fan. The glycol solution and the outdoor cold air are exchanged in the plate heat exchanger. The cooled glycol solution enters into the air conditioners in the inner area and exchange with mixed air. Then the mixed air enters into the inner room with lower temperature and supply cooling. The temperature of glycol solution rise up, it comes back to the plant heat exchanger in the outdoor again, exchange heat with the cold air in the outdoor and continue this cycling after the temperature is lowered. This way of heat exchange is usually used in the heat recycling system.
It is a very energy-saving way that use glycol as a refrigerant to introduce the cold air in the outdoors to supply cooling for the inner area. All we need to do is to install a plant heat exchanger in the outdoor when it works, the cold water equipment closed, opening the fan and the air conditioners can bring cooling for the inner area. In this way, we can save energy and reduce the cost.
Recomendações relacionadas
-
Função da bomba de água do refrigerador de água industrial
1558The water pump is one of the important auxiliary components of the refrigeration system of the industrial water chiller. Many industries will use the industrial water chiller, but many people don't know much about the equipment. This time, lneya r...
Ver detalhes -
Relação entre o mau desempenho da refrigeração e o refrigerante em baixas temperaturas industriais
1467O efeito do sistema de refrigeração do frigorífico industrial de baixa temperatura está diretamente relacionado com o refrigerante. Uma vez que o refrigerante vaza, a capacidade de refrigeração será insuficiente, de modo que as pressões de sucção e exaustão são rela...
Ver detalhes -
Quais são os factores que influenciam o frigorífico industrial com menos 200 graus?
1667Para utilizar melhor o frigorífico industrial com uma temperatura de menos 200 graus, é necessário compreender alguns factores de influência e como evitá-los. A temperatura do óleo terá um efeito importante na viscosidade do frigorífico industrial...
Ver detalhes -
Falhas comuns e análise da causa do resfriador refrigerado a ar
1915Durante a utilização de equipamento de refrigeração arrefecido a ar, é inevitável encontrar algumas falhas comuns. Os usuários precisam entender as possíveis causas das falhas e fazer as soluções correspondentes a tempo, de modo a tornar a produção e a operação mais estável...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor