Como instalar e utilizar o sistema de controlo da temperatura do reator?
Many users are going to start the installation after purchasing the reactor temperature control system. What should be paid attention to during installation?
When installing the reaction kettle of the reactor temperature control system, it is necessary to pay attention to whether the reactor is damaged during transportation and installation. The magnetic stirrer on the upper part of the kettle lid should be avoided, and the reaction of the reactor temperature control system should be avoided. The kettle operating room requires good ventilation and meets explosion protection requirements. The reaction kettle equipped with the reactor temperature control system was mounted on a support, and balanced on the four supports to keep the equipment perpendicular to the ground. Anti-static grounding devices should be installed on the flammable and explosive equipment of the reaction medium to eliminate static electricity.
If it is a high-temperature, high-speed magnetic stirrer, the reaction kettle equipped with the reactor temperature control system should be filled with lubricating oil at the bearing oil filling port before use. In the future use, the lubricating oil should be added regularly from the oil filling hole. The reactor equipment for the reactor temperature control system is supplied with cooling water in the outer water jacket of the magnetic stirrer before starting. The lower end is the water inlet and the upper end is the water outlet. A separate cooling water system should be used. The cooling water is not allowed. The cooling coil is then passed through the cooling coil in the kettle to enter the cooling water jacket of the magnetic stirrer.
The control cabinet and frequency converter of the reactor temperature control system equipment should be placed in a separate, electrically controlled workshop with dry and well ventilated. When the stirring speed of the reactor temperature control system equipment is greater than 80r/min, the motor cannot be started directly at the working speed, and the stirring speed should be slowly increased by the inverter. Otherwise, the stirrer resistance is too large, causing the magnetic stirrer to overload and causing the agitation to damage or burn the motor. The reaction kettle of the reactor temperature control system needs to be tested for tightness according to the working pressure. It is kept under inert gas for 15~30 minutes to check whether the whole equipment is leaking. If there is no leakage, it can be put into production.
When using the reactor temperature control system, it is necessary to pay attention to the switch is not suitable too much, so as not to damage the overall performance of the reactor temperature control system and the life of the fitting.
Recomendações relacionadas
-
Processo de reparação de avarias no compressor de máquinas de ciclo quente e frio fechadas
963A máquina de ciclo quente e frio de tipo fechado da LNEYA adopta a tecnologia de refrigeração auto-cascata de máquina única, e o seu compressor também utiliza o compressor de marca, que é mais estável em termos de desempenho. Portanto, é fácil escolher uma série de compressores...
Ver pormenores -
How to extend the service life of heat transfer oil in dynamic temperature control system?
952In the chemical industry, the heat transfer medium of the heat transfer oil of the dynamic temperature control system of the reactor is mainly determined by the heat transfer oil itself, the operating temperature of the heat transfer oil, the dyna...
Ver pormenores -
Que equipamento é assistido por refrigeradores de baixa temperatura na indústria farmacêutica?
850A utilização de refrigeradores de baixa temperatura na indústria farmacêutica destina-se principalmente a satisfazer os requisitos rigorosos de controlo da temperatura em vários processos de produção, a fim de garantir a qualidade do produto e a segurança da produção. Os refrigeradores de baixa temperatura...
Ver pormenores -
Troubleshoot the main points of failure of the high and low temperature cooling system
1211When the industrial high and low temperature cooling system is in use, what is the general reason if the temperature cannot drop down? How should we deal with such failures? Let's first analyze the principles and methods of industrial cooling. The...
Ver pormenores