Como instalar e utilizar o sistema de controlo da temperatura do reator?
Many users are going to start the installation after purchasing the reactor temperature control system. What should be paid attention to during installation?
When installing the reaction kettle of the reactor temperature control system, it is necessary to pay attention to whether the reactor is damaged during transportation and installation. The magnetic stirrer on the upper part of the kettle lid should be avoided, and the reaction of the reactor temperature control system should be avoided. The kettle operating room requires good ventilation and meets explosion protection requirements. The reaction kettle equipped with the reactor temperature control system was mounted on a support, and balanced on the four supports to keep the equipment perpendicular to the ground. Anti-static grounding devices should be installed on the flammable and explosive equipment of the reaction medium to eliminate static electricity.
If it is a high-temperature, high-speed magnetic stirrer, the reaction kettle equipped with the reactor temperature control system should be filled with lubricating oil at the bearing oil filling port before use. In the future use, the lubricating oil should be added regularly from the oil filling hole. The reactor equipment for the reactor temperature control system is supplied with cooling water in the outer water jacket of the magnetic stirrer before starting. The lower end is the water inlet and the upper end is the water outlet. A separate cooling water system should be used. The cooling water is not allowed. The cooling coil is then passed through the cooling coil in the kettle to enter the cooling water jacket of the magnetic stirrer.
The control cabinet and frequency converter of the reactor temperature control system equipment should be placed in a separate, electrically controlled workshop with dry and well ventilated. When the stirring speed of the reactor temperature control system equipment is greater than 80r/min, the motor cannot be started directly at the working speed, and the stirring speed should be slowly increased by the inverter. Otherwise, the stirrer resistance is too large, causing the magnetic stirrer to overload and causing the agitation to damage or burn the motor. The reaction kettle of the reactor temperature control system needs to be tested for tightness according to the working pressure. It is kept under inert gas for 15~30 minutes to check whether the whole equipment is leaking. If there is no leakage, it can be put into production.
When using the reactor temperature control system, it is necessary to pay attention to the switch is not suitable too much, so as not to damage the overall performance of the reactor temperature control system and the life of the fitting.
Recomendações relacionadas
-
Solução de arrefecimento líquido para centros de dados LNEYA Unidade de distribuição CDU arrefecida a líquido
1961Chiller de arrefecimento líquido para centros de dados LNEYA CDU
Ver detalhes -
Como manter um desempenho estável do arrefecedor de óleo de laboratório biofarmacêutico?
14041. Um ambiente de trabalho adequado para evitar várias falhas do refrigerador de óleo no laboratório biofarmacêutico precisa de proporcionar um melhor ambiente operacional para o equipamento. Manter o ambiente limpo e arrumado, reduzir o impacto de vários factores...
Ver detalhes -
Which part of the chip testing system requires high and low temperature control?
1368In the chip testing system, the environmental control equipment requires high and low temperature control. Specifically, this section mainly includes the following two key devices: 2. Temperature control system: For certain testing app...
Ver detalhes -
Como lidar com o problema de arrefecimento dos grandes compressores de congelação rápida?
2167Existem muitos tipos de compressores em congeladores rápidos de grande escala, e as marcas e modelos de compressores são diferentes de acordo com os diferentes modelos. Uma vez que a temperatura do compressor é demasiado elevada, pode causar algumas falhas, pelo que o arrefecimento é também uma...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor