Introduction To The Preparation Of Low Temperature Chiller’ Operation
Why do low temperature chiller need to be ready for operation? We must be very clear that only when we are ready to check the low temperature chiller can we run the equipment better, can we run it more efficiently.
Before running the refrigerador de baixa temperatura, we need to check the refrigerant, water and electrical equipment, and check the oil separator liquid level, the correct oil position should be in the oil mirror center line between the line.
Be careful to check that all the pressure gauges for the low temperature chiller are open, and whether the oil thermometer has been inserted with the lubricating oil, and check or open all the valves on the oil road that they should be completely open.
Push the start button, the low temperature chiller starts, and then wait to see whether the oil pump is turning correctly, the oil pressure difference is not low than the surface pressure of 0.05-0.3Mpa, and the pressure difference of the oil filter does not exceed 0.1Mpa. Turn the coupling and operate the energy control valve at the same time, so that the unloading indication goes from 0%–100%, then 100%–0%, then manually stop the oil pump.
Try low temperature chiller with hand disc compressor coupling, no card resistance phenomenon shows the normal state. Open the exhaust valve on the compressor, water supply to the oil cooler, and water temperature depends on the oil temperature (the nozzle oil temperature is better to be 40 –55 c). At the same time, water supply to the condenser and evaporator , finally cover the main motor power supply, and the power lamp is on, then the low temperature chiller can be used normally.
With these detailed preparations, it is certain that the low temperature chiller can be better used to achieve the lowest cost and maximum operational efficiency.
Recomendações relacionadas
-
Área de aplicação do sistema de controlo de refrigeração e arrefecimento a alta temperatura
1495O sistema de controlo de refrigeração e arrefecimento a alta temperatura é utilizado para suportar reactores de vidro, evaporadores rotativos, tanques de fermentação e calorímetros; amplamente utilizado em petróleo, química, metalurgia, bioquímica, física, testes e...
Ver detalhes -
Como é que o sistema de refrigeração do frigorífico criogénico é drenado?
2434Users who use ultra-low temperature chillers will encounter some problems when they are not used for a long time, such as poor cooling performance and loud sound. These problems are more common, but some refrigeration systems need to be well under...
Ver detalhes -
Como é que o refrigerador de baixa temperatura se aplica à indústria de moldes?
1592Como todos sabem, o refrigerador de baixa temperatura é amplamente utilizado, especialmente na linha de moldes. Então, todos sabem como ele funciona na indústria de moldes? Se você não sabe, vamos dar uma olhada comigo. Ao usar o resfriador de baixa temperatura para resfriar o molde, ...
Ver detalhes -
Como resolver a falta de capacidade de arrefecimento do sistema de ciclo de arrefecimento de semicondutores?
1713O sistema de ciclo de arrefecimento de semicondutores é um dispositivo para arrefecer a parte de aquecimento do semicondutor no equipamento de refrigeração. É normalmente utilizado para testar peças de CI de semicondutores, peças electrónicas para automóveis, componentes de fibras ópticas,...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor