Porque é que os refrigeradores de etilenoglicol podem ser utilizados para reacções de polimerização e acoplamento
1. Polymerization heating
Generally, the raw materials of
polymerization reaction are some flammable solvents, and heating up quickly may
cause local temperature to be too high and cause accidents. Every
polymerization reaction has its proper reaction temperature. If the temperature
is changed outside, the reaction efficiency will be reduced, and the
polymerization reaction will release more reaction heat. Changing the proper
temperature will be immeasurable, especially in industrial production. accident.
Therefore, Wuxi Guanya’s refrigeration and heating integrated machine can be
selected to adjust the temperature of the polymerization reaction to ensure the
safety in the process of production.
Among the polymerization reactors, more
than 80% of the polymerization reactors are tank reactors. There are two types
of reactors without stirring and those with stirring. Among them, the reactor
with stirring is used more. Because the heat exchange device has endothermic
and exothermic reactions, it is necessary to set up a heat exchange device to
provide and take away heat. The main structure is With jacket heat transfer,
inner cooling part heat transfer and external circulation heat transfer, Wuxi
Guanya’s refrigeration and heating equipment can just meet the regulation of
exothermic and endothermic heat.
The kettle type polymerization reactor can
be used for the production of a variety of polymers; it can be used in
low-viscosity polymer systems as well as high-viscosity polymer systems; it can
be used in both batch operation and continuous operation. The basic structure
of the polymerization reactor mainly includes a kettle body, a stirring device,
a stirring accessory, a heat transfer device, and a sealing device. According
to the reaction materials and operating requirements, the kettle type
polymerization reactor has a variety of types, such as thin and long type and
short and fat type, which are mainly determined by the ratio of length to
diameter.
2. The characteristics of the coupling
reaction
The coupling reaction rate is slow, and the
solubility of the reaction product often changes greatly. After precipitation,
the viscosity of the material is greatly increased, which seriously affects the
mixing of the material, and is easy to form a material package and cause the
reaction to be incomplete. The application of the microchannel reactor to the
coupling reaction enhances the mixing of materials and is beneficial to
increase the reaction rate. It is equipped with high and low temperature
integrated equipment. When the reaction temperature is in the range of 5-25℃, as the
temperature rises, the reaction rate increases, and the residence time required
for the complete reaction becomes shorter, but at the same time, the low flow
rate is The reaction will accelerate.
The dynamic temperature control of LNEYA
glycol chiller is mainly used in dynamic constant temperature control of high
pressure reactor cold and heat source, dynamic constant temperature control of
double-layer glass reactor cold and heat source, dynamic constant temperature
control of double-layer reactor cold and heat source, constant temperature of
microchannel reactor Control; small thermostat control system, steaming system
temperature control, material low temperature high temperature aging test,
combined chemical cold source heat source constant temperature control,
semiconductor equipment cooling heating, vacuum chamber cooling heating
constant temperature control.
Recomendações relacionadas
-
Peças de equipamento aeroespacial teste criogénico congelador refrigeração instruções de resolução de problemas
1895A temperatura de entrada da água de arrefecimento é demasiado baixa Congelador de temperatura ultrabaixa para testes de temperatura ultrabaixa de componentes de equipamento aeroespacial À medida que a temperatura da água de arrefecimento diminui, a pressão de descarga do compressor, a temperatura de...
Ver detalhes -
Description of requirements for installation of glycol chiller
1560Generally, after purchasing the equipmentwith the glycol chiller manufacturer, the installation manual will bedistributed to the user together. So, what should be paid attention to wheninstalling the glycol chiller?In summer, glycol chillers ar...
Ver detalhes -
O efeito do aquecimento arrefecimento Tradutor
1418The whole liquid circulation of the heating and cooling circulator is closed with the expansion vessel. The expansion vessel and the liquid circulation are adiabatic and do not participate in the liquid circulation. This is just a mechanical conne...
Ver detalhes -
Descrição da fonte de alimentação do chip condutor no sistema de controlo da temperatura de ensaio de chips
1382O sistema de controlo de temperatura de teste de chip é principalmente para o equipamento de teste de fonte de calor frio para vários chips de unidade. Antes da operação do sistema de controlo de temperatura de teste de chips Wuxi Guanya, o utilizador precisa de conhecer a potência do chip de acionamento. I...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor