Pontos de atenção para a inspeção diária do equipamento de controlo de baixa temperatura a menos 30℃
The low temperature control equipment at minus 30 degrees Celsius is a refrigeration unit or also called a refrigeration unit. The difference from the chiller is the temperature range. It is a commonly used low-temperature equipment in the industry and needs to operate for a long time. So what points should be paid attention to in daily inspection during operation?

1. Power supply part inspection
Before installation, the low temperature control equipment of minus 30 degrees Celsius will make a plan for the surrounding installation environment, circuit and power supply. If the conditions and standards are suitable, the installation will be carried out, and the installation will be re-planned if the conditions are not suitable. After a long period of use, check the power supply part to see if the power supply accessories are damaged, whether the wires inside and outside the equipment are aging, and whether there is damage. If there are problems, check and correct them in time.
2. Refrigerant inspection
The refrigeration effect in the low temperature control equipment of minus 30 degrees Celsius is a more critical part. If the refrigerant leaks, it will affect the refrigeration temperature, fail to achieve the expected refrigeration effect, and affect the overall work progress. While checking the refrigerant of the low temperature control equipment at minus 30 degrees Celsius, check whether the joints of the relevant parts are loose or cracked. If there is a problem, solve it quickly to avoid refrigerant leakage. If a refrigerant leak is found, it needs to be supplemented, and it needs to be added in accordance with relevant standards.
3. Pipeline inspection
The low temperature control equipment of minus 30 degrees Celsius needs to be inspected after a certain period of time to see if there is any leakage. If a leak is found, it needs to be repaired, and then used after checking that there is no leakage.
Recomendações relacionadas
-
Shutdown method in the case of high-precision high-low temperature circulator failure
1074The high-precision high-low temperature circulator is one of the equipments used in the pharmaceutical and chemical industry to support various reactors. If users encounter an abnormal power outage during use, they should pay attention to operatio...
Ver pormenores -
O que significam os códigos de avaria dos chillers arrefecidos a ar
1177Geralmente, as pessoas verão 2 áreas no painel de controlo do dispositivo, nomeadamente a área PV e a área SV. A primeira exprime a temperatura específica e a segunda serve para regular a temperatura. Quando ocorre uma avaria, o PV apresenta o número de ...
Ver pormenores -
Instruções de instalação da máquina de água quente e fria 5P
1025A máquina de água quente e fria 5P é utilizada em várias indústrias e é utilizada para tratamento a frio. Então, quais são os problemas necessários durante a instalação e manutenção? Se a unidade de compressor de refrigeração da unidade de água quente e fria 5P não tiver vibração...
Ver pormenores -
Aplicação de equipamento de circulação com controlo uniforme da temperatura no processo de destilação
1077destilação arrefecimento aquecimento aplicação do sistema
Ver pormenores