Detailed Operating Instructions of Industrial Chiller
The installation procedures of water
chiller include:
1. During installation, please check
whether the machine is damaged and select a suitable place for installation and
future maintenance. The site for installing the unit must be the floor or
installation pad, with a levelness within 6.4mm, and can bear the operating
weight of the unit.
2. The chiller shall be placed in the
machine room with room temperature of 4.4-43.3 ℃, and there shall be enough space around and above the unit for
daily maintenance.
3. At one end of the unit, a pipe
extraction space for cleaning the condenser tube bundle shall be reserved, and
door holes or other holes at appropriate positions can also be used.
4. Select water pipes with appropriate pipe
diameter, cooling system and cold water system when the unit operates at
maximum power, and connect them correctly.
5. For ordinary applications, the water
flow velocity through the evaporator and condenser is allowed to be between
1.0-3.6m/s.
6. The water flow shall be stable under any
load.
7. All cooling water pipes shall be
designed and installed according to the conventional method. The chilled water
pump shall be located on the inlet pipe of the chiller to ensure the positive
pressure and flow in the unit. When piping, damping pipes shall be set to
ensure proper elasticity, and prevent the water in the evaporator from being
drained when the water pump stops.
8. The pipeline shall be firmly supported
independent of the chiller to avoid stress on the components of the chiller.
9. In order to reduce noise and vibration,
it is better to install vibration isolator on the pipeline.
10. In order to use the chiller
economically and effectively, it is recommended to invite water treatment
experts to analyze the water supply quality of evaporator and condenser. Poor
water quality will cause scale, affect heat transfer, or produce corrosion
precipitation, affect the performance of the unit and increase operation and
maintenance costs.
11. Generally speaking, proper water
treatment and regular cleaning can maintain its good performance.
12. Please install a filter at the inlet of
the water pipe and clean it regularly.
13. After leak test, all nozzle openings
must be treated with rust prevention.
14. In order to facilitate daily
maintenance, the user can take some (or all) of the following measures: the
pressure gauge and stop valve with cock can be installed on the inlet and
outlet pipes of cooling water and chilled water, close to the chiller as far as
possible;
Lifting rails and beams can be erected
above the equipment to facilitate maintenance.
Recomendações relacionadas
-
Método de controlo do refrigerador de ensaio de semicondutores para satisfazer os requisitos de temperatura
1780O campo biofarmacêutico requer uma temperatura de alta precisão para controlar a atividade das enzimas e a produção de produtos; o campo da indústria química requer temperaturas específicas para que as reacções químicas se processem de forma estável; a indústria eletrónica...
Ver detalhes -
Câmara multifuncional de ensaio de impacto a alta e baixa temperatura elemento de preço de qualidade
1756Especialmente na aquisição de câmaras multifuncionais para ensaios de impacto a alta e baixa temperatura, o fator preço determina frequentemente a qualidade dos seus produtos. Afinal de contas, os fabricantes têm de sobreviver. É pouco provável que vendam equipamentos de alta qualidade...
Ver detalhes -
Diretamente na exposição | Shanghai Automotive Testing Expo
1923Tipo de veículo de aplicação:1. veículo elétrico híbrido; 2. veículo elétrico puro; 3. carro com motor a hidrogénio; 4. veículo elétrico com célula de combustível; 5. veículo elétrico de gama alargada; 6. outros veículos de energia nova;Campo automóvel de aplicação:É especialmente d...
Ver detalhes -
O requisito de instalação do chiller industrial
1588(1) A fonte de alimentação do chiller adopta uma linha de alimentação trifásica de quatro fios (R, S, T) ligada à linha de incêndio da fonte de alimentação, (N) linha zero, (G) linha de terra..,
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor