Basic Structure of Industrial Water Chiller
Basic structure of industrial water chiller:
Industrial water chiller consists of
compressor, condenser, evaporator, expansion valve and other accessories.
1. Compressor: in the industrial water chiller
system, the compressor is the power to ensure refrigeration. The compressor is
used to increase the pressure of the refrigerant in the system and make the
refrigerant circulate in the refrigeration system to achieve the purpose of
refrigeration.
2. Condenser: high temperature and high
pressure Freon of the refrigeration system enters the condenser after coming
out of the compressor, releases a lot of heat to the cooling medium, and then
is cooled and liquefied.
3. Evaporator: when the Freon liquid of the
refrigeration system enters the expansion valve for throttling and is sent to
the evaporator, it belongs to the vaporization process. At this time, it needs
to absorb a lot of heat to gradually reduce the valence and mass temperature to
achieve the effect of refrigeration and cooling.
4. Expansion valve: in the refrigerant
system flow chart of the industrial water chiller, we found that there is a
small part between the outlet of the condenser and the inlet of the evaporator,
which is called thermal expansion valve. It is a throttling and depressurizing
part to reduce the condensation pressure of the refrigerant to the evaporation
pressure. Therefore, its role in the refrigeration system is essential. It is
connected with the refrigeration compressor, evaporator, condenser It is also
called the four components of the refrigeration system.
5. Other accessories: including drying
filter and high and low pressure controller. The drying filter is non
detachable. The internal structure adopts molecular sieve structure, which can
remove a small amount of impurities and water in the pipeline, so as to purify
the system. The high and low pressure controller plays a protective role in the
refrigeration system.
Recomendações relacionadas
-
Common faults of plate heat exchangers in new energy vehicle inspection
2170The reason for the excessive pressure drop of the new energy vehicle detection is that the running system pipeline is not properly purged, especially in the newly installed system pipeline, many dirt (such as welding slag) enters the interior of t...
Ver detalhes -
Como escolher um refrigerador de água desionizada para laboratório?
2057A água pura refere-se normalmente à água que foi tratada para remover impurezas, iões, matéria orgânica, etc. Exemplos comuns incluem água destilada, água de osmose inversa e água desionizada. A água desionizada tem uma baixa condutividade devido à...
Ver detalhes -
Perspectivas de desenvolvimento de sistemas térmicos de ensaio eletrónico
1366Para a sociedade moderna, a conservação de energia e a redução de emissões é também uma tarefa importante. No desenvolvimento de semicondutores, chips, circuitos integrados e outras indústrias, o sistema térmico de teste eletrónico pode testar eficazmente a sua temperatu...
Ver detalhes -
Nota de fábrica da máquina de alta e baixa temperatura à prova de explosão
1870Explosion-proof high and low temperature integrated machine is the main product of LNEYA production and sales. It adopts dynamic temperature control system and fully closed pipeline design. The operation effect is relatively stable. What common pr...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor