Função da bomba de água do refrigerador de água industrial
The water pump is one of the important auxiliary components of the refrigeration system of the industrial water chiller. Many industries will use the industrial water chiller, but many people don’t know much about the equipment. This time, lneya refrigeration will talk about the role of the water pump of the industrial water chiller.

The function of the water pump of the industrial water chiller is to provide pressure and water flow according to the needs of the system. The chilled water pump is the water pump, also known as the circulating water pump. Of course, the chilled water pump is not only the water pump in the industrial water chiller system, but also may exist in the cooling water system of the air-cooled water chiller.
The water pump of industrial water chiller can determine the water flow of chilled water, that is, the water flow of chilled water is not only affected by the size and capacity of the water tank, but also affected by the chilled water pump. The water flow can determine the range of refrigeration temperature to some extent. When the same cooling capacity is transmitted with chilled water as refrigerant, the larger the water flow is, the higher the temperature of the cooling capacity will be.
Water flow is controlled by chilled water pump, so there is a close relationship between chilled water pump and industrial water chiller refrigeration. The specific reasons are as follows: while the water flow of the industrial water chiller increases, the cooling capacity of the chilled water per unit area will decrease. Although the total cooling capacity remains unchanged, the cooling capacity per unit area of the chilled water has decreased. Therefore, if the chilled water flow is large, the cooling effect will become worse and the temperature will become higher, However, this does not mean that the refrigeration capacity of the compressor and the whole chiller system becomes worse.
The chilled water system includes water pipeline, chilled water tank, water pump, etc. the specific parameter selection and xing’shi selection of the water pump are closely related to the model of the industrial chiller. Whether the type of the water pump and the parameter model can be selected will directly determine the refrigeration capacity of the industrial chiller and even whether the industrial chiller can work normally.
About the role of industrial water chiller water pump, that’s it. If you don’t understand, please consult us:sales@lneya.com!
Recomendações relacionadas
-
Impact and Solution of Excess Exhaust Temperature of Industrial Chiller Units
1175Industrial water chiller compressor exhaust temperature determines whether the equipment can stably and efficiently run. The common problem of compressor is excess exhaust temperature. Once the situation appears, it is easy to make industrial chil...
Ver pormenores -
Descrição analítica dos acessórios utilizados no refrigerador de baixa temperatura
847O chiller de baixa temperatura ainda usa uma quantidade maior de equipamento de água de resfriamento em nosso equipamento de refrigeração usual. Ao usá-lo, você deve primeiro entender o princípio do resfriador de baixa temperatura e vários acessórios para operar melhor...
Ver pormenores -
A diferença entre pequenos chillers arrefecidos a ar e pequenos chillers arrefecidos a água no trabalho
1431Os diferentes tipos de chillers são divididos em dois tipos de acordo com o estilo, aparência, configuração incorporada, forma do condensador, etc. A dissipação de calor da unidade através do condensador aletado é chamada de chiller pequeno refrigerado a ar.
Ver pormenores -
Método de manutenção do condensador em unidades de refrigeradores de água
1084O condensador arrefecido a ar é utilizado principalmente em refrigeradores de água arrefecidos a ar. Utiliza o ar como meio de arrefecimento. Devido à presença frequente de poeiras ou outros resíduos no ar, algumas destas poeiras ou resíduos cairão na superfície exterior das alhetas do condensador. Sobre...
Ver pormenores