When the explosion-proof type hot and cold integrated machine is used at the end of the day or when it is not used by the standby, be sure to disconnect the cooling water connection pipe, clean the remaining cooling water in the pipe, and store it in a dry place to prevent freezing and expansion. Damage to machine parts (such as coolers, pumps, connecting copper pipes). The method of removing residual water is as follows:
1. The water sequence series needs to disconnect the cooling water and hot water inlet and outlet pipes and open the corresponding ball valve. Take the air gun to the hot water (outlet) inlet and let the residual medium inside the system discharge from the cooling water inlet (cooling) The water outlet is discharged from the inlet due to the electromagnetic valve. It is determined that there is no water in the pipeline and it can be stopped.
2. The standard explosion-proof type hot and cold integrated machine needs to disconnect the connecting pipe of the cooling water inlet and outlet, open the ball valve and let the machine be in a cooling state. When the cooling electromagnetic valve is opened, take the air gun and blow it into the cooling water inlet to make it from the water outlet. Discharge, determine that there is no water in the pipeline and then stop.
Kindly note, please be sure to disconnect the cooling water connection pipe when the equipment is not in use, and clean the remaining cooling water/heat transfer oil in the pipe, and store it in a dry place.
In the winter, when you do not need the explosion-proof type hot and cold machine, you need to pay attention to turn off the explosion-proof hot and cold machine and clean it as well, so as to avoid the residue affecting the performance of the explosion-proof hot and cold machine.
Recomendações relacionadas
-
Parte do equipamento LNEYA Função Introdução
19771.1.1 The industrial chillers(SUNDI series) is applied to cooling and heating the reactor, especially suitable for the process of heating and exothermic process. It can control the material temperature in the reactor, can choose the program contro...
Ver detalhes -
Ethylene glycol refrigeration unit made a strong attack and created LNEYA brand in 12 years
2013Performance enhanced positioning When performing the cooling and heating reaction, in many cases, the refrigerant cannot cool the object to be cooled by itself. Therefore, we need a coolant (or refrigerant) to cool the refrigeration system in a re...
Ver detalhes -
Método de seleção de 0 ℃ ~ 5 ℃ líquido de congelamento para resfriador industrial de temperatura ultrabaixa
1492À medida que os requisitos para a produção de processos se tornam cada vez mais elevados, os refrigeradores industriais de temperatura ultrabaixa são necessários para fornecer líquido criogénico abaixo de 5 graus ou mesmo mais de 100 graus negativos em alguns processos químicos de síntese,...
Ver detalhes -
Dispositivo de arrefecimento de teste da bateria Instruções de configuração comum do chiller
1956Em condições normais de utilização, o dispositivo de arrefecimento de teste da bateria Chiller tem de ser descoberto a tempo quando ocorre qualquer anomalia. Isto requer uma compreensão clara da configuração básica do dispositivo de arrefecimento de teste de bateria Chiller. A bateria...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor