A solução para o alarme de falta de refrigerante no termóstato de aquecimento e arrefecimento totalmente fechado
What should I do if the fully enclosed heating and cooling thermostat alarms for lack of refrigerant? I believe that many customers will encounter this problem when they use it. In fact, this is relatively simple. As long as we know the principle of the lack of refrigerant alarm, it can be solved very well. Today I will share two points with you so that everyone will encounter this problem. It can be solved very quickly.

When we encounter a refrigerant shortage alarm in a fully enclosed heating and cooling thermostat, the first thing we have to do is to check to see if the liquid level on the expansion tank of the fully enclosed heating and cooling thermostat is at the normal level, if it expands at this time The liquid level of the fuel tank is lower than the low level, then this alarm is caused by the lack of oil in the system. What we need to do is to add new heat transfer oil in time until the system has a stable pressure and the liquid level of the expansion tank is at the normal level. It can be solved.
There is another situation that will also cause the fully enclosed heating and cooling thermostat to alarm for lack of refrigerant. That is, an alarm occurs after a period of use. At this time, we also need to check the liquid level of the expansion tank. If the heat transfer oil is lower than the low level, there must be a leak in the pipeline, which needs to be found and repaired in time. If it is not the leakage problem, then Most of it should be that the liquid level float switch of the expansion oil tank touches the wall of the expansion oil tank, causing the liquid level switch to not work normally. At this time, we need to remove the liquid level switch and re-reinforce it. The main reason for this situation may be due to The fully enclosed heating and cooling thermostat is caused by slight vibration during use.
The above are two solutions for the lack of refrigerant alarm. The alarm is a fully enclosed heating and cooling thermostat’s built-in protection, mainly to prevent the heating tube from burning dry, so when we encounter this problem, we can solve it in most cases according to the two methods shared by the editor. If it is solved No way to contact LNEYA after-sales technical support.
Recomendações relacionadas
-
Sistema de aquecimento do refrigerador de processo da torre de destilação
1056Distillation towers and distillation tower processes indeed require chillers and heating systems to maintain temperature control during the process, ensuring effective separation and purification operations. The top temperature of the ...
Ver pormenores -
How to deal with organic waste gas treatment refrigerant leakage?
1145In the process of organic waste gas treatment, if it is found that the refrigerant leaks, it is recommended to treat it in time. LNEYA organic waste gas treatment professional manufacturer then analyzes the knowledge of organic waste gas treatment...
Ver pormenores -
Como resolver a condensação do teste do motor do veículo elétrico é demasiado elevada?
1079A pressão de condensação do ensaio do motor do veículo elétrico aumentará, a função de compressão aumentará, a capacidade de arrefecimento diminuirá, o coeficiente de arrefecimento diminuirá e o consumo de energia aumentará. A razão para t...
Ver pormenores -
Quais são as aplicações da unidade de refrigeração criogénica de extração supercrítica de CO2?
1022Com o desenvolvimento contínuo da tecnologia de extração supercrítica de co2, os dispositivos de refrigeração criogénica de extração supercrítica de co2 têm atraído a atenção de muitas indústrias devido às suas próprias caraterísticas, e têm sido amplamente utilizados em...
Ver pormenores