Dicas para a deteção de fugas no congelador de baixa temperatura
Soaking leakage detection
The sensibility of soaking leakage detection is higher than bubble test,which is usually applied for small Freon freezer unit. When using it, the equipment prohibited from contacting water in the system should be discharged, like all kinds of relays and electrical control device. Taking advantage of warm water during the bubble test, because its surface tension is smaller than cold water, forming bubbles more easily. As an editor of Low Temperature Freezer, I want to tell you that the leakage point will be discovered simply if accompanied by intense light source. After the completion of soaking leakage detection, the surface ought to be dried with compressed air, preventing the metal from corrosion.
Halide torch and its leakage detection
These are the specialized devices for detecting the Freon freezer unit system. When Freon refrigerating fluid encounters hot cooper parts, different colored flames will be casted for F2, C12 and Br contain the elements of halogen, helping find out the leaking point.
Vacuum leak test
When freezer unit system passes the pressure leakage detection, it should also go through the vacuum leak test since some pasts exist one-way leaker. Only pressure and vacuum leakage detection both conform to the standard can the leakproofness of cooling system can be ensured. Besides, the system is evacuated, so can water at the same time , esped dcially the Freon system. Therefore, evacuation and desiccation play essential roles in debugging the unit.
Should the uses for low temperature freezer be understood, the users will have a better try! Visit LNEYA to know more about low temperature freezer price.
Recomendações relacionadas
-
Cuidados a ter com o congelador de temperatura ultra baixa
15691. Requisitos do ambiente do equipamento: Para manter o exterior do frigorífico criogénico limpo e ventilado, é necessário manter a posição horizontal do frigorífico criogénico estável e garantir que não há artigos diversos à volta. 2. Mana...
Ver detalhes -
Caraterísticas estruturais do chiller de recirculação industrial
1322Na reação química, existem requisitos rigorosos para a temperatura de reação. É necessário aumentar a temperatura para uma temperatura adequada para realizar a reação química sem problemas. Após a reação, a temperatura na re...
Ver detalhes -
Thermal oil heating system installation and fault analysis
1975When the heat transfer oil heating system device is installed, it is necessary to pay attention to the system to avoid some faults during installation. If a fault occurs, it is necessary to understand the faults related to the heat transfer oil he...
Ver detalhes -
Caixa de ensaio completa para o ensaio de veículos de energia nova cheia de óleo de transferência de calor
1974A fim de assegurar o correto funcionamento da máquina, a caixa de ensaio integrada de inspeção de veículos de energia nova deve assegurar que não permanecem bolhas de ar no sistema, assegurar que a saída do meio de transferência de calor está ligada à interface inferior do...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor