Método de controlo da paragem do refrigerador arrefecido a água de uma única caldeira de reação
The reaction kettle water cooled chiller has a wide range of accessories and equipment. In actual use, it needs to be provided with regular rest time. In order to maintain the stable performance of the refrigerator during long-term operation, it is necessary for the user to master the method of stopping the operation according to the actual use requirements, and to reduce the excessive wear of the equipment.
1. When it is necessary to shut down, first consider ensuring that the reactor freezer is within the shutdown range before performing all shutdown operations. In order to avoid the generation of high pressure, the user needs to close the suction stop valve to stop the operation of the compressor.
2. After completing the shutdown of the refrigerator compressor, it is necessary to operate the oil pump. Return the slide valve of the freezer to the 0-scale position so that the load reduction reaches zero. At this time, the oil pump will immediately stop all operations.
3. For the reaction kettle water cooled chiller, the operation of the water pump and cooling water tower needs to be stopped in the latter step. After stopping this type of equipment, the entire power supply can be turned off and the entire shutdown process can be completed. Ensure that the reactor water cooled chiller is in the shutdown state.
Precautions for reactor shutdown:
1. If the machine stops for a long time, special treatment is required. Including the condenser and the evaporator, the refrigerant needs to be completely pumped to the condenser, and at the same time all the water sources are discharged to avoid problems such as corrosion.
2. After the shutdown is completed, various accessories need to be carefully tested. The shutdown process is more particular, and the correct shutdown steps can prolong the service life of the equipment.
For the reactor freezer that has been shut down for a long period of time, careful testing is required to ensure that the equipment is kept away from various corrosive substances.
Recomendações relacionadas
-
Common faults of plate heat exchangers in new energy vehicle inspection
2165The reason for the excessive pressure drop of the new energy vehicle detection is that the running system pipeline is not properly purged, especially in the newly installed system pipeline, many dirt (such as welding slag) enters the interior of t...
Ver detalhes -
Wuxi Guanya analisa como julgar as condições de refrigeração do resfriador de água refrigerada para você
1367Ao comprar um refrigerador de água refrigerada, se você quiser saber a qualidade dos chillers, você pode ver a condição de refrigeração dos chillers. O efeito de refrigeração dos bons chillers é relativamente estável e eficiente em operações de longo prazo...
Ver detalhes -
Princípio de funcionamento do termóstato de refrigeração e aquecimento para a indústria química
1635No processo de seleção do termóstato especial de refrigeração e aquecimento para a indústria química, a potência de aquecimento e a pressão e caudal do meio de transferência de calor são também factores a considerar. Diferentes matérias-primas têm diferentes...
Ver detalhes -
Como limpar o sistema de arrefecimento da bateria dos veículos de energia nova?
1388The battery cooling system of the new energy model first unscrews the three screws on the upper part of the wet curtain, holds the louvers on the upper part of the wet curtain, gently pulls the wet curtain outward and then lifts it up slightly to ...
Ver detalhes