Quais são as principais vantagens dos refrigeradores de óleo para a indústria biofarmacêutica?
In the refrigeration system of the oil cooler in the biopharmaceutical industry, the compressor, the evaporator and the condenser are the indispensable parts of the refrigeration system. The condenser is the equipment that emits heat, which combines the heat absorbed in the evaporator with the compressor The heat converted by the work is transferred to the cooling medium to take away together, which is responsible for the important components of the refrigeration system. If the function decreases, it will directly affect the refrigeration capacity.
There are two main types of condensers used in biopharmaceutical industrial oil coolers: air-cooled condensers and water-cooled condensers. Depending on the type of condenser, the method of cleaning the scale is also different.
1. The air-cooled condenser uses air as the cooling medium. Since there is often dust in the air, some of the dust will stick to the outer surface of the condenser fins. Over time, the cooling effect of the condenser will become worse. Especially in places where the environment is relatively harsh, it should be cleaned regularly. The cleaning method is: pure dust can be cleaned with compressor air, etc. If there is a lot of dirt, a non-corrosive cleaning agent should be used to clean the heat pipe and fins to achieve the purpose of improving the heat dissipation effect.
2. For water-cooled condensers, the main problem is to remove scale. The cleaning cycle depends on the water quality. If the water quality is poor, it can be cleaned at least once a year; if the water quality is good, it can be cleaned once every 2 to 3 years.
3. It can be cleaned with special cleaning fluid for heat exchangers. The specific operation method is: remove the condenser, release the accumulated water, and then clean the liquid in the tube until the water outlet has the position where the solution flows out.
The performance of the condenser of the oil cooler in the biopharmaceutical industry will gradually decline if it is used for a long time. As a result, the condensing pressure of the system will be higher than the condensing pressure during normal operation. Regularly protect and maintain the condenser. Here is a brief introduction to the two commonly used condenser protection and maintenance.
Recomendações relacionadas
-
Parâmetros do pequeno sistema de liquefação por condensação de gás
1741Durante o processo de carga e descarga de gasolina e reabastecimento de veículos, e recolha de gás de alta concentração da fábrica de produtos químicos. Um ou dois métodos no processo de adsorção ou condensação, ou a conversão de óleo e gás a partir de um gás...
Ver detalhes -
A unidade de arrefecimento de baixa temperatura - efeito de arrefecimento de 120 graus é fiável?
1915LNEYA é especializada na produção de unidades de resfriamento criogênico de fluido único, a faixa de temperatura de resfriamento é de -150 graus a -5 graus, que pode atender a diferentes requisitos de temperatura de resfriamento. Os produtos são amplamente utilizados em aplicações de baixa temperatu...
Ver detalhes -
Heating and cooling cycle machine maintenance boot operation instructions
1867When users choose the heating and cooling cycle machine, they often have to choose the right conditions for their own work, and their knowledge of maintenance and start-up also needs our attention. After the installation of the heating and cooling...
Ver detalhes -
Fault Hint of Cryogenic Chiller Refrigeration System
1420When the high and low pressure of the system are higher than normal, there is usually air or excessive refrigerant in the system. At this time, we need to re-vacuum, and then add a proper amount of refrigerant to solve this problem. But there are ...
Ver detalhes