The Noise Analysis of Precision Chiller
Generally speaking, even the most sophisticated refrigerating equipment will also have some trouble when used for a long time. If the noises present in the precision chiller after prolonged use, I am sure that it appears some faults. So let’s go deeper to see where these noises are from.
The noise of compressor
The compressor is in the core position of the inner structure of the precision chiller. In general, compressors include screw and stroll, you can pick up one as what you need. Once the compressor has some noise, the first thing you should do is to check out if the expansive valve is open excessively; if so, you ought to adjust it. Next, you should see if the freezing medium is overmuch; if so, you had better remove the needless refrigerators.
The noise of water pump
It is attributable to the water quality mainly if the water pump has some noises. I suggest that water treatment should proceed according to the requirement of the chillers.
The accessories lack lubricant
The configuration of most of chillers is made of metal. Once the accessories are short of lubricant, the frictions can not be avoided, making some noises. Besides, you have to keep maintenance in daily life to reduce the rate of faults.
Oil starvation because of overload
You can find out whether the compressor is fuel elan when there are some noises. If it is, you can refuel it. To check if the compressor is overloaded will help you solve it in time.
Through the introduction of precision chillers, you must have a better understanding. If you are eager to further study, you can follow Guanya Refigeration Technology Co., Ltd.
Recomendações relacionadas
-
Como funcionam os refrigeradores de semicondutores CVD e PVD?
1699O princípio de funcionamento dos refrigeradores utilizados nos processos de deposição química de vapor (CVD) e de deposição física de vapor (PVD) de semicondutores consiste principalmente em remover o calor gerado durante o processo através da circulação de água de arrefecimento ou de...
Ver detalhes -
Que sectores são utilizados para equipamentos de ensaio de dispositivos semicondutores?
1787Semiconductor device test equipment is used more in the semiconductor industry. So, how much do you know about the applicable semiconductor conductors? The properties of this substance are still recommended to the user. In general, substances can ...
Ver detalhes -
LNEYA: Foco no controlo da temperatura TCU para construir instrumentos chineses avançados internacionais
1583Wide temperature range: LNEYA's Chinese and production-grade multi-reactor refrigeration heating temperature control system (temperature control unit TCU) temperature range from -25 ° C to 200 ° C, of course, you can also customize other temperatu...
Ver detalhes -
Nota de utilização da pequena caixa de ensaio de choque quente e frio
1575Small thermal shock test chamber is non-explosion-proof product (explosion-proof needs to be customized), please do not use it in the environment with flammable or explosive gas. In order to avoid small thermal shock, the test box is faulty, pleas...
Ver detalhes
LNEYA Refrigeradores industriais Fabricante Fornecedor