O refrigerador de água de temperatura ultrabaixa 60P consome demasiada energia e precisa de atenção
Os refrigeradores de água de temperatura ultrabaixa 60p de diferentes fabricantes têm diferentes configurações de desempenho e diferentes consumos de energia. Se verificar que o consumo de energia é demasiado elevado, deve verificar atempadamente se existe algum problema...

1. When there is a fault:
If the 60p ultra-low temperature water chiller equipment is faulty and the cooling performance is continuously reduced, the enterprise must be more cautious when using it. When operating the equipment, if the enterprise ignores the existence of various common faults, although the equipment can be used normally for the time being, the operation safety of the equipment will be directly and seriously affected.
2. When running for a long time:
If the operating time of the 60p ultra-low temperature water chiller equipment is relatively long, and in the process of operation, the company does not provide sufficient rest time for the equipment. Therefore, the security of enterprise use will also be threatened. Wuxi Guanya Constant Temperature Refrigeration Technology Co., Ltd. LNEYA recommends that enterprises can rationally formulate a plan for the operating time of 60p ultra-low temperature water chillers, or use multiple installations for alternate operation.
3. Environmental factors:
When companies use 60p ultra-low temperature water chillers, if there are many inappropriate factors in the environment, the same will happen that energy consumption continues to increase. Therefore, to choose a place with a better environmental location and a workshop with a large enough space, the equipment needs to be installed at the corners or in the middle. Only in this way can the correct location be selected to help the company complete the task efficiently.
Resumir
The above problems may cause excessive energy consumption of the 60p ultra-low temperature water chiller. When users encounter the above problems during use, they can contact the relevant after-sales technicians to solve them in time.
Recomendações relacionadas
-
Introduction to mixed solution of glycol chilling systems (glycol chillers)
877Glycol chillers are industrial refrigeration systems that use a type of antifreeze called glycol, mixed with water, to lower the freezing point in the application of the chilling system. Glycol is a class of organic compounds that belong to the ...
Ver pormenores -
Sistema de arrefecimento e aquecimento da caldeira de dissolução de cristalização de 200L
824For the needs of 200L crystallization dissolution kettle cooling and heating system applications, this type of equipment is usually used in the crystallization, dissolution and other processes in the fields of chemical industry, pharmace...
Ver pormenores -
Organic waste gas treatment device noise description
1367With the increasingly stringent environmental requirements, various manufacturers have paid more and more attention to their own organic waste gas treatment. LNEYA organic waste gas treatment equipment specializes in the treatment of various organ...
Ver pormenores -
Precautions for use of minus 95 degrees cryogenic liquid bath cold trap
1042The minus 95 degree low temperature liquid bath cold trap (that is, the refrigerator that we often say) is a common refrigeration unit in refrigeration equipment. The rational use of the unit can not only avoid the failure of the unit, but also ma...
Ver pormenores