Pesquisar toda a estação

Grande refrigerador de água

  • High Performance and Low Noise

These compressors not only perform excellently but also operate quietly. Even during long-term operation, they can run for over 100,000 hours without failure.

  • Intelligent Temperature Control

The unit features segmented or stepless energy regulation. It adjusts flexibly according to the thermal load requirements during production, ensuring optimal cooling efficiency.

  • Energy-Efficient Control

By using the outlet temperature of the refrigerant as a control point, the unit’s control center adjusts the compressor load by controlling the movement of the energy regulation valve, achieving actual energy savings.

outdoor chillers

Potência de aquecimento 3.5kW~15kW

precisão de temperatura ±0.3℃

large water chillers

Potência de aquecimento 2.5kW~10kW

precisão de temperatura ±0.3℃

screw water chillers

Bomba de circulação MAX 5m³/h~28m³/h 2bar

precisão de temperatura ±0,5℃

screw chiller plant

Bomba de circulação MAX 2,4m³/h~12,1m³/h 2bar

precisão de temperatura ±0,5℃

water cooled screw chillers

Bomba de circulação MAX 2,3m³/h~12m³/h 2bar

precisão de temperatura ±0,5℃

industrial water coolers

Bomba de circulação MAX 2,3m³/h~12m³/h 2bar

precisão de temperatura ±0,5℃

Modelo LG2-75W LG2-100W LG2-140W LG2-180W LG2-230W LG2-280W
Gama de temperaturas  -25℃~5℃
Capacidade de arrefecimento
-20℃
kW 80 111 158 206 259 318
Kcal/hr*10³ 68.8  95.5  135.9  177.2  222.7  273.5 
Potência 3N/400V/50HZ
Cooling input power at (-20℃) 56 74  105  136  166  205
Compressor Formulário semi-closed double screw compressor
Heat control range 25%~100%
Chilled water Formulário   Plate, dry, overflow or falling film heat exchanger
Chilled water volumeT/H 24 32  46  59  75  92 
Water pressure drop 40~80
Tamanho da ligação DN65 DN80 DN100 DN125
Água de arrefecimento Formulário Horizontal tubular heat exchanger
Cooling water volumeT/H 26 35 50 65 80 99
Water pressure drop 40~80
Tamanho da ligação DN80 DN100 DN125 DN150

LARGE WATER CHILLER ‘S APPLICATIONS

É geralmente utilizado para arrefecimento de máquinas e fusos no processo de produção, controlo de temperatura de vários medicamentos e processos de preparação na área farmacêutica e controlo de temperatura de reações químicas, como cristalização e síntese química ou laboratorial, bem como em novos testes de veículos de energia e semicondutores.

Serviço global

Atendeu mais de 30.000 clientes.
Exportado para mais de 20 países.

Patentes de certificação

Obteve a certificação CE, certificação SGS, certificação ISO.

Serviço pós-venda

Fornece treinamento técnico abrangente.
Com soluções 24/7.

Equipa profissional

Fundada em 2010, com 15 anos de experiência no setor.
20% of employees are technicians.

Controlo de qualidade

Visual inspection.
Performance test.
Electrical safety test.

Contacte-nos agora para obter detalhes e preços de refrigeradores de parafuso.

Gama de temperaturas
Consider the production temperature requirements first. Different applications (such as air conditioning and low-temperature projects) have different temperature needs.
Cooling Capacity and Single Unit Cooling Capacity
The cooling capacity directly affects the energy efficiency and operating economy. When designing a chiller system, multiple units should be arranged to ensure production continues even if one unit is down.
Energy Consumption
Consider both electrical and steam consumption, especially for large systems. The goal is to maximize energy efficiency by considering the combined use of electricity, heat, and cooling.
Environmental Protection
Focus on the noise level and the impact of the refrigerants on the environment. Avoid using refrigerants that damage the ozone layer or are harmful to the environment, ensuring that the system meets environmental standards.
If you have any doubts about choosing the right chiller, feel free to contact us. Our 24/7 customer service team is available to provide professional consultation and offer custom-designed solutions.

The air cooled screw compressor chiller is mainly composed of the screw compressor, expansion valve, condenser, evaporator, and other components.
Below is the translation of the specific parts and their functions:
Compressor de parafuso  
It is the power source of the air-cooled screw chiller system. Its main function is to extract the vapor from the evaporator in a timely manner, maintain low temperature and low pressure, and increase the pressure and temperature of the refrigerant vapor through compression, creating conditions for the heat transfer of the refrigerant vapor to the external environment.
Condensador  
The air-cooled screw chiller uses a finned condenser. The condenser is a heat exchange device that works by transferring the heat of the high-temperature, high-pressure vapor discharged from the compressor to the surrounding cooling medium.
Válvula de expansão  
Since the high-pressure, normal-temperature refrigerant liquid cannot be directly sent into the low-temperature, low-pressure evaporator, it needs to be depressurized and its temperature reduced. Therefore, the expansion valve is used to obtain low-temperature, low-pressure refrigerant, which is then sent to the evaporator to absorb heat and vaporize.
 Evaporador  
Similar to the condenser, the evaporator is also a heat exchange device. It evaporates the low-temperature, low-pressure refrigerant liquid into vapor, absorbs heat from the cooled medium, reduces the temperature of the cooled medium, and provides low-temperature chilled water to achieve cooling. The evaporator, like the condenser, must have a sufficiently large area to work effectively.

*
*
Submeter....
Enviado com sucesso!
A submissão falhou! Tente novamente mais tarde
Erro de correio eletrónico!
Erro telefónico!

Adicione o nosso gestor de conta através do código QR abaixo