Pesquisar toda a estação

Unidade chiller-aquecedor

SUNDI -10℃~+150℃

SUNDI-10℃~150℃ chiller heater unit has both cooling and heating capabilities, temperature range -10℃~150℃, heat transfer medium temperature control accuracy ±0.5℃.
Fabricante de chillers de origem, toda a linha suporta OEM.

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 1)
<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 2)
Capacidade de refrigeração 2.1kW~1.5kW
<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 3)
Potência de aquecimento 3.5kW~15kW
<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 4)
Medium temp accuracy ±0.5℃
<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 5)
Consumo de energia

SUNDI -10℃~150℃ chiller heater unit is a temperature control system that integrates heating and cooling functions. It is an entry-level product in the highly dynamic temperature control system series.

Atualmente, as unidades chiller-aquecedor SUNDI -10℃~150℃ têm sido amplamente utilizadas em farmacêutica, biotecnologia, testes de materiais aeroespaciais, destilação e concentração, entre outros cenários, para garantir a precisão da temperatura e a repetibilidade dos resultados em experimentos e processos de produção

SUNDI- 135
135W
155
155W
175
175W
1A10
1A10W
1A15
1A15W
Gama de temperaturas  -10℃~+150℃
Precisão da temperatura média ±0.5℃
Precisão da temperatura do material ±1℃
Potência de aquecimento 3.5 5.5 7.5 10 15
refrigeração
capacidade
150℃ 3.5 5.5 7.5 10 15
20℃ 3.5 5.5 7.5 10 15
-5℃ 2.1 3.3 4.2 6 9
Flow、pressure max
L/min bar
35 35 50 50 75
1 1 1.2 1.2 1.2
Água de arrefecimento
@20℃
1300L/H
1,5bar~4bar
ZG1/2
1800L/H
1,5bar~4bar
ZG3/4
1800L/H
1,5bar~4bar
ZG3/4
2400L/H
1,5bar~4bar
ZG3/4
3600L/H
1,5bar~4bar
ZG1
Dimensão(cm) 45*70*160 45*70*160 55*70*175 55*70*175 70*85*185
Potência 380V 50HZ 6.7kW 9,5 kW 12kW 15.5kW 23kW

Chiller portátil de ar e água

Controle de temperatura de três pontos

Podem ser compilados 20 programas

A chave para garantir alta precisão e alta eficiência

Advantages of Chiller Heater Unit

Tipo O combo chiller-aquecedor SUNDI-10℃~150℃ possui duas opções: chiller-aquecedor portátil de ar e chiller-aquecedor portátil de água. Sustentabilidade A unidade chiller-aquecedor portátil SUNDI-10℃~150℃ adota refrigerante ecológico que não esgota a camada de ozônio, usando R404A ou R507C. Sistema de circulação totalmente fechado A unidade chiller-aquecedor SUNDI-10℃~150℃ adota um design de tubulação totalmente fechado, que não absorve umidade em baixa temperatura e não volatiliza o meio em alta temperatura

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 6)
<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 7)
A chave para garantir alta precisão e alta eficiência

Aplicações da unidade chiller-aquecedor

Seja em testes de materiais, desenvolvimento de produtos ou produção de precisão, um ambiente de temperatura preciso e estável é crucial
 
As unidades chiller-aquecedor podem fornecer um ambiente de temperatura adequado para reatores de alta pressão, reatores de vidro de camada dupla, reatores de camada dupla, reatores de microcanais, etc.

Fabricação de semicondutores/eletrônica
A produção, embalagem e teste de componentes eletrônicos de precisão exigem simulação de diferentes condições de temperatura para garantir a estabilidade de desempenho
 
Os combos chiller-aquecedor são usados para pesquisa de desempenho de materiais aeronáuticos e controle de temperatura durante testes de componentes

OUTRO MODELO para SISTEMAS DE CONTROLE DE TEMPERATURA DINÂMICA

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 8)

SUNDI -10℃~+150℃
Unidade chiller-aquecedor

Capacidade de resfriamento 2,1 kW~15 kW
Potência de aquecimento 3.5kW~15kW

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 9)

SUNDI -25℃~+200℃
Circulador de aquecimento/resfriamento

Capacidade de resfriamento 1,8 kW~200 kW
Potência de aquecimento 3,5 kW~200 kW

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 10)

SUNDI -45℃~+250℃
Chiller de aquecimento

Capacidade de resfriamento 0,25 kW~200 kW
Potência de aquecimento 2,5 kW~200 kW

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 11)

SUNDI -60℃~+250℃
Aquecedor de água e chiller

Capacidade de resfriamento 0,25 kW~60 kW
Potência de aquecimento 2,5 kW~60 kW

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 12)

SUNDI -80℃~+250℃
aquecedor de água de refrigeração

Capacidade de resfriamento 0,3 kW~80 kW
Heating power 3kW~80kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 13)

SUNDI -90℃~+250℃
combinação de refrigerador e aquecedor

Cooling capacity 0.5kW~80kW
Potência de aquecimento 5,5 kW~80 kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 14)

SUNDI -100℃~+100℃
Aquecedores-chiller de recirculação

Capacidade de resfriamento 0,7 kW~80 kW
Potência de aquecimento 5,5 kW~80 kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 15)

SUNDI-320
Chiller portátil

Capacidade de resfriamento 0,4 kW~1,5 kW
Potência de aquecimento 2 kW
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Adicione nosso gerente de conta via o QR code abaixo

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 16)
<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 17)
<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 18)

You can trust Chiller Heater Unit factory

A LNEYA conta com mais de 400 colaboradores, dos quais 20% são técnicos. Quer se trate de engenheiros de aplicação, engenheiros de instalação e comissionamento, instrutores de formação, consultores técnicos, equipas de vendas ou equipas de atendimento ao cliente, todos eles passaram por uma formação abrangente e avaliações rigorosas. Dispomos de um conjunto completo de sistemas de gestão da produção, gestão da qualidade, gestão de marketing e gestão de serviços.

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 23)

Serviço global

Atendido mais de 30.000 clientes.
Exportado para mais de 20 países.

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 24)

Patentes de certificação

Obteve a certificação CE, certificação SGS, certificação ISO.

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 25)

Serviço pós-venda

Fornecer treinamento técnico completo.
Com soluções 24/7.

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 26)

Equipa profissional

Fundada em 2010, com 15 anos de experiência no setor.
20% dos funcionários são técnicos.

<trp-post-container data-trp-post-id='12758'>chiller heater unit</trp-post-container>(images 27)

Controle de qualidade

Inspeção visual.
Teste de desempenho.
Teste de segurança elétrica.

Can’t find a suitable chiller heater unit?Contact us now to get details and prices

Oferecemos serviços de reparo de garantia no local e com retorno. O processo de substituição simples e rápido e o atendimento 24/7 garantem que sua eficiência de produção e experiência do usuário não sejam afetadas

Claro. Nosso alcance de personalização inclui, mas não se limita a, tipo, tamanho, temperatura, potência, material da carcaça, bomba de circulação, à prova de explosão, sistema de controle, interface de comunicação de dados, tamanho de entrada e saída, tamanho da tela sensível ao toque colorida, etc. do chiller-aquecedor de processo
 
 Se você não sabe como projetar seu chiller, nossos especialistas em chiller terão prazer em ajudá-lo a projetar a configuração de unidade chiller-aquecedor mais econômica de acordo com seu orçamento

*
*
Submitting….
Enviado com sucesso!
A submissão falhou! Tente novamente mais tarde
Erro de correio eletrónico!
Erro telefónico!