How to Choose the Best Chiller for a 20L Reactor System

- How to Upgrade an Old Chiller to Improve Efficiency
- Chiller Tanks Comparison Expansion Tank vs Buffer Tank
- Expansion Tanks in Semiconductor Chillers
- How Explosion-Proof Chillers Work Principles and Design
- Agosto 2025
- Julho 2025
- Junho 2025
- Maio 2025
- Março 2025
- Fevereiro 2025
- Janeiro 2025
- Dezembro 2024
- Novembro 2024
- Outubro 2024
- Setembro 2024
- Agosto 2024
- Julho 2024
- Junho 2024
- Maio 2024
- Abril 2024
- Março 2024
- Fevereiro 2024
- Setembro 2023
- Julho 2023
- Junho 2023
- Maio 2023
- Janeiro 2023
refrigerador arrefecido a ar refrigerador refrigeradores Congelador de montagem a frio refrigerador de refrigeração circulador de arrefecimento e aquecimento sistema de arrefecimento e aquecimento cooling water chiller Double-Layer Glass Reactor sistema de controlo dinâmico da temperatura Controlo da temperatura de líquidos fluorados congelador refrigerador de refrigeração a gás circulador de aquecimento industrial chiller industrial cooling industrial freezer frigorífico industrial jacket reactor refrigerador de refrigeração líquida refrigerador de baixa temperatura news pharmaceutical chiller process chiller reactor chiller reactor cooling reactor cooling heating aquecimento do reator arrefecimento reactor system bomba de circulação refrigerada refrigeration chiller refrigerador de parafuso refrigerador de semicondutores refrigerador de teste de semicondutores sundi tcu controlo da temperatura câmara de ensaio termóstato refrigerador de temperatura ultra baixa refrigerador de ensaio de veículos refrigerador de água refrigerador arrefecido a água wtd
20L reactor systems are commonly found in laboratory R&D, small-scale, and pilot-scale experiments. Temperature control of the reactants within the reactor impacts reaction efficiency, product quality, and the safety of equipment and personnel.
Chillers are common reactor accessories, helping to precisely control reaction temperatures. This article explains the temperature control requirements and key selection parameters for a 20L reactor chiller. It also compares the pros and cons of various chiller types to help you choose the optimal solution for your application.
Temperature Control Requirements for 20L Reactor Systems
A 20L reactor may be small, but in some exothermic or endothermic chemical reactions, the amount of heat within it fluctuates dramatically. Therefore, a chiller is essential to regulate the reaction temperature, preventing both overheating and reaction slowdown caused by low temperatures. A chiller that meets the temperature control requirements of a 20L reactor should have the following characteristics:
• Stable temperature control with minimal output temperature fluctuation.
• Quickly respond to temperature changes in the reactants, eliminating temperature overshoot and temperature lag.
• Suitable operating temperatures for both low and high temperatures. Well-sealed and equipped with safety devices, some applications require explosion-proof chillers to ensure equipment and personnel safety.

Key Parameters for Chiller Selection
When selecting a chiller for a 20L reactor system, consider the following parameters:
Capacidade de arrefecimento
Cooling capacity is a key parameter to consider when selecting a chiller. It represents the device’s ability to remove heat. The cooling capacity required for a 20L reactor depends on the reaction type, the amount of heat released, and the ambient temperature. It’s important to estimate the maximum heat release based on the reactor’s heat load , and allow for some margin to prevent the chiller from operating at full capacity for extended periods or malfunctioning under abnormal heat loads. Based on our experience in customer selection, a 20L reactor requires a cooling system with a cooling capacity range of 2-10kW. The specific value should be determined based on the actual heat load.
Gama de temperaturas
Different reactions release different amounts of heat and require different optimal temperatures. The reactants in a 20L reactor may need to be cooled from ambient temperature to 0°C or even lower, or heated to over 100°C. Therefore, the chiller’s temperature range should be determined based on your actual operating conditions. We generally recommend customers choose a chiller with a temperature range 5°C wider than the actual maximum and minimum operating temperatures and capable of rapid temperature changes.
Coolant Type
The type of coolant affects both heat transfer efficiency and the operational stability of the equipment. This is because different coolants have significantly different physical properties at different temperatures. Furthermore, some coolants can react chemically with certain materials, potentially affecting equipment operation.
Common coolants include water, glycol-water mixture, and thermal oil. Water has a freezing point of 0°C and is therefore not used in low-temperature chillers to prevent freezing. Glycol-water mixture is generally used in chillers above -40°C. Thermal oil is well-suited for high-temperature conditions, but it is also expensive. Coolant selection should be based on the operating temperature and cooling system materials.
Flow Rate
Coolant flow rate affects heat transfer efficiency and system response speed. Too low a flow rate prevents the coolant from fully removing heat from the reactants, while too high a flow rate can increase pipeline pressure and damage the jacket. To ensure smooth operation of the cooling system, the flow rate must be adjusted to the optimal value.
Temperature Control Precision and Responsiveness
Temperature control accuracy significantly affects reaction stability. Modern chillers generally use PID control systems and multiple Pt100 sensors, achieving accuracy of ±0.1°C or even higher (LNEYA semiconductor chillers can achieve ±0.02°C). Response speed is crucial for the ability of the coolant outlet temperature to adjust promptly to the reactant temperature.
Comparison of Different Chiller Types
There are many types of chillers, categorized by condensation method, application scenario, and function. Common equipment used for 20L reactor systems is primarily the following:
Industrial Air-Cooled Chillers
The condenser of an air-cooled chiller is fan-cooled, dissipating heat directly into the air. It eliminates the need for auxiliary cooling water piping. Therefore, it has a small footprint and is easier to install. It is well-suited for installation in laboratories or small workshops. It is also more cost-effective than a water-cooled system, making it a good choice for cooling a 20L reactor.

Resfriadores de semicondutores
Semiconductor chillers are commonly used in processes such as wafer fabrication, chip testing, and ion implantation, but their use is not limited to the semiconductor industry. Its high temperature control accuracy and fast response speed make it suitable for processes requiring stringent temperature requirements. Available in a wide range of performance and sizes, it’s a good choice for reactions in your reactor requiring strict temperature control.

Chiller heaters
Chiller heaters offer both cooling and heating functions, making them ideal for reactions requiring temperature cycling or rapid ramping. Some units also feature a temperature profile function, allowing you to set ramp times and rates. The unit automatically adjusts the output temperature based on this profile. This feature ensures consistent results for every reaction.

Practical Considerations and Recommendations for Model Selection
Besides the above equipment parameters, what else should you consider when purchasing a reactor chiller?
Budget and Cost-Effect
Different budgets offer different equipment configurations. You need to balance chiller performance and cost to select a chiller that meets your reaction requirements while being economical. If you’re unsure how to choose a configuration within your budget, a chiller manufacturer can provide professional design assistance.
Size and Installation Space
The reactor’s operating environment determines the size and type of chiller. For smaller laboratories, air-cooled chillers are more advantageous. For larger workshops, water-cooled chillers offer higher cooling efficiency.
After-Sales Service and Spare Parts
The average lifespan of a chiller is about 10 years, during which it will undergo frequent maintenance and spare parts replacement. Without reliable after-sales service and technical support, you could run into numerous problems. Therefore, when choosing a chiller for your 20L reactor, choose a reputable brand with a comprehensive after-sales process and the ability to provide spare parts.
User Reviews
Peer feedback on chillers is more valuable. If a chiller supplier lacks experience providing chillers for your application, they will struggle to fully consider the challenges you may face in real-world conditions and will be unable to design and produce cooling equipment suitable for your reactor.
Conclusão
Although a 20L reactor system is smaller, it still requires a precise and stable temperature control system. LNEYA maintains long-term partnerships with numerous pharmaceutical and chemical companies and has extensive experience in customizing reactor chillers for a variety of applications, including new drug synthesis, pilot production, API preparation, formulation testing, and material synthesis. We have extensive design and production experience.