Descrição do princípio de refrigeração no controlo da temperatura de bolachas semicondutoras
In the operation of the semiconductor wafer temperature control refrigeration system, a state transition of a certain working fluid is used, and the necessary heat Q0 is extracted from the heat source of a lower temperature, and the heat Qk is sent to the heat source of the tropical heat through a storage process of the consumption power W. In this process, Qk = Q0 + W is taken from the conservation of energy.
In order to achieve temperature control of semiconductor wafer temperature migration, a process of lowering the temperature of the refrigerant to a lower temperature environment is forcibly performed, and heat is continuously extracted from the object to be cooled, and this is achieved within the boundary of the refrigeration technique. The process has several basic steps: phase change refrigeration: the use of liquid evaporation at low temperatures or the dissolution or sublimation of solids at low temperatures to extract heat from the object being cooled. Normal air conditioners are all such cooling steps. Gas expansion refrigeration: The high pressure gas can reach a lower temperature after adiabatic expansion, so that the low pressure gas can be reheated to cool. Gas eddy current refrigeration: After the high pressure gas is expanded by the vortex tube, it can be respectively hot and cold air flow, and can be cooled by the reheating process of the cool air flow. Thermoelectric cooling: The direct current is passed through the semiconductor thermopile, which can have a cold effect at one end and a thermal effect at the other end.

The temperature of the semiconductor wafer is controlled during operation. At the high temperature, no heat transfer medium evaporates, and it can be realized without pressure. -80 to 190 degrees, -70 to 220 degrees, -88 to 170 degrees, -55 to 250. Degree, -30 ~ 300 degrees continuous temperature control. The principle and function of semiconductor wafer temperature control have many advantages for the user: Because only the heat transfer medium in the expansion chamber is in contact with the oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60 degrees), the reduction can be achieved. The heat transfer medium is oxidized and absorbs moisture in the air.
In the semiconductor wafer temperature control, the principle of refrigeration is as shown above. When the user controls the temperature control of the semiconductor wafer, the user should pay attention to the principle of refrigeration, and better operate the semiconductor wafer temperature control after understanding.
Recomendações relacionadas
-
Como escolher a bomba acessória no ensaio de baterias de veículos de energia nova?
930O teste de bateria de veículos de energia nova desempenha um papel mais importante no desenvolvimento de veículos de energia nova. No processo de operação, a bomba é o equipamento de suporte chave no equipamento de teste LNEYA, que também é preocupado pelas pessoas. Então, como ...
Ver pormenores -
Instruções de manutenção do compressor do equipamento de tratamento de condensação de gás Vocs
958The vocs gas condensing treatment equipment is an important equipment in the process of exhaust gas treatment. Among them, the compressor is one of the main components, and its performance is affecting the operating efficiency of the entire vocs g...
Ver pormenores -
Precauções para um pequeno refrigerador de água de laboratório antes e depois do arranque
1163Na indústria farmacêutica e química, os pequenos refrigeradores de água de laboratório são equipamentos de refrigeração amplamente utilizados, que são frequentemente utilizados em várias chaleiras de reação para reacções de refrigeração. Para manter o funcionamento estável do equipamento de re...
Ver pormenores -
The difference between a large refrigeration and heating circulator and a test chamber
8941. For the high temperature test under special circumstances, the high and low temperature test chamber may not meet the requirements. Generally speaking, the high temperature upper limit of the high and low temperature test box is 200 ℃, and its ...
Ver pormenores