Como escolher a conduta para a recuperação por adsorção de condensação vocs?
Dispositivo vocs de recuperação de adsorção de condensado no momento da seleção, a configuração do seu sistema precisa de ser clara para poder comprar com confiança, então, os pontos de atenção da conduta vocs de recuperação de adsorção de condensado, como escolher? Condensado...
Condensate adsorption recovery vocs should be as short as possible in the pipeline connection with the controlled substance, reduce bending, when the pressure of the circulation pipeline is too large, the pipeline pressure is insufficient, it will cause the pipeline, the reactor to crack, high temperature, The possibility of spraying low-temperature heat-conducting medium may cause injury, burns, frostbite and ignition of flammable materials, pollution caused by loss of reactants, property damage, and even poisoning of personnel.
The pipeline connection should be sealed and firm, and it has measures such as anti-vibration, grounding, rust prevention and pressure keeping. It can effectively prevent the pipeline from vibrating and corroding, causing cracks and leakage, and there is a danger of static electricity.
Condensate adsorption recovery vocs When connecting with controlled equipment, pay attention to the link of the pipeline, do not have the interface error, generally the liquid outlet corresponds to the inlet, the inlet is connected to the outlet, if it is water-cooled, The water outlet corresponds to the water return port, the water inlet corresponds to the water outlet, and the liquid discharge port (used when the heat medium is replaced) corresponds to the waste liquid collection and collection port.
In the selection of the pipeline, if the use of improper / damaged hoses and / or hose joints, it will lead to personnel injury, it is recommended that the metal insulation hose temperature range -60 ~ 250 ° C; pressure ≤ 2.5 bar.
Condensate adsorption recovery vocs When you carefully configure the metal insulation hose and other pipelines, please refer to their pressure and overpressure capabilities, caliber, and temperature range. At this time, it is necessary to consider the head pressure of the circulating pump inside the equipment. It is recommended that the condensing adsorption recovery vocs should select a pipeline of good quality and sufficient volume such as seamless steel pipe.

When selecting insulation materials, the temperature range of condensing adsorption recovery vocs should be considered first. It is necessary to select the flame retardant material. The temperature range of the insulation material should include the temperature range of the equipment, and there is a margin greater than 30 °C. When the user ignores this problem, There is a possibility of fire. There is also a sufficient amount of insulation material package for condensing adsorption recovery vocs, otherwise the equipment control will not achieve the expected results.
Each component of the condensing adsorption recovery vocs device is very important for its performance. Therefore, it is recommended that the user select the specific parameter configuration and then make a decision when selecting the condensing adsorption recovery vocs.
Recomendações relacionadas
-
Solução para o derrame de óleo do circulador de arrefecimento e aquecimento do reator
939When we use some reactor cooling and heating circulators, we will find that the system pressure fluctuates up and down as the temperature rises, and the oil tank is overflowing. So what are the reasons for these conditions in the cooling and heat...
Ver pormenores -
Quais são as medidas de manutenção dos refrigeradores de glicol em funcionamento diário?
1187No funcionamento diário do refrigerador de glicol, se a manutenção não for efectuada, o efeito de arrefecimento será reduzido. Por isso, para melhorar a eficiência de funcionamento, recomendamos que efectue a manutenção diária necessária. Refrigerador...
Ver pormenores -
Quais são os principais pontos de manutenção regular do refrigerador de recirculação?
925Os chillers de recirculação são utilizados frequentemente na indústria, e as partes geradoras de calor de vários dispositivos requerem chillers de recirculação, pelo que a eficiência operacional é muito importante. Durante o tempo de funcionamento do chiller de recirculação, é necessário ...
Ver pormenores -
What are the factors related to the selection of heating and refrigeration circulators?
962Heating and refrigeration circulators are used in many laboratory projects. They are usually equipped with reactors and reactors for cooling, heating and temperature control. Then, what factors are related to the selection of heating and cooling i...
Ver pormenores