TCU temperature control model selection and technical parameter description
TCU temperature control is also a two-cycle unit single-fluid temperature control system. When selecting the model, it is very important for the whole temperature control reaction. Only the appropriate reaction system is used to exotherm and absorb the whole reaction process. The heat responds to the entire control, so the choice of model is very important.
TCU temperature control model: SR-10
Model SR-10 with operating temperature range of -120~200°C, suitable reaction vessel is 50L-250L, circulating pump flow pressure is controlled at 3m3/h1.5bar, circulating pump can not be adjusted, auxiliary heating power is 10KW, pre- The interface of the heat exchange module is DN25, and electric power, steam, hot oil, hot water, cooling water, chilled water and ultra-low temperature medium can be used as primary energy.
TCU temperature control model: SR-20
Model SR-20 with operating temperature range of -120~200°C, suitable reaction vessel is 100L-500L, circulating pump flow pressure is controlled at 2.4~6.6m3/h1.5bar, circulating pump control can be adjusted by frequency or fixed speed. The auxiliary heating power is 20KW, and the interface of the preheating heat exchange module is DN32.
TCU temperature control model: SR-38
Model SR-38 with operating temperature range of -120~200°C, suitable reaction vessel is 300L-1000L, circulating pump flow pressure is controlled at 5~12m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 38KW, and the interface of the preheating heat exchange module is DN40.
TCU temperature control model: SR-60
Model SR-60 with operating temperature range of -120~200°C, suitable reaction vessel is 500L-2000L, circulating pump flow pressure is controlled at 11~25m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 60KW, and the interface of the preheating heat exchange module is DN65.
TCU temperature control model: SR-95
Model SR-95 with operating temperature range of -120~200°C, suitable reaction vessel is 1000L-5000L, circulating pump flow pressure is controlled at 20~50m3/h2.5bar, circulating pump control can be adjusted by frequency or fixed speed, auxiliary The heating power is 95KW, and the interface of the preheating heat exchange module is DN80.

In addition, the energy conversion of TCU temperature control is carried out by heat exchanger and electric heating. In the temperature control mode selection, the material temperature control and jacket temperature control can be freely selected, and the material temperature control accuracy is ±1 °C. Inch / inch color touch screen. The temperature control of the whole TCU is a fully enclosed system. There is no oil mist at high temperature and no moisture in the air at low temperature. The TCU temperature control system does not increase the fluid pressure due to high temperature during operation, and automatically supplements the heat transfer medium at low temperature.
Recomendações relacionadas
-
Powertrain test cooling system-chiller maintenance
1133The powertrain test cooling system-chiller is one of the cooling systems. It has the characteristics of higher application efficiency and lower total energy consumption, and has generally been favored by many companies. However, no matter what kin...
Ver pormenores -
Introdução e vantagens do sistema de refrigeração criogénica
1167O refrigerador criogênico de fluido único de tamanho médio produzido por nossa empresa tem uma faixa de temperatura de resfriamento de -150 ℃ a -5 ℃, velocidade de resfriamento rápida, segura e confiável, usada para resfriamento líquido rápido, aplicada a alta tecnologia, como bioquímica, congelamento ...
Ver pormenores -
Princípio de funcionamento dos refrigeradores de ar industriais LNEYA
1027O refrigerador de ar industrial é um permutador de calor que utiliza o ar para arrefecer o fluido quente. O fluido quente no tubo é aquecido através da troca de calor entre a parede do tubo, a aleta e o ar exterior, que é normalmente fornecido pelo ventilador. O nosso I...
Ver pormenores -
Um novo ponto de partida para o desenvolvimento de dispositivos de teste de semicondutores
1027Durante muito tempo, devido ao rápido desenvolvimento de circuitos integrados, a indústria de componentes foi prejudicada por várias restrições em materiais e processos. Os ensaios de produção de semicondutores e pastilhas são particularmente importantes, pelo que se trata de uma nova...
Ver pormenores