What is the function of high temperature heat transfer fluid system?
The high temperature heat transfer fluid system adopts a fully closed circulation system, so that there is no oil mist during high temperature operation, and high temperature refrigeration can be realized. It is the temperature control equipment used in many industries at present.

1. High temperature heat transfer fluid system is used with most experimental equipment, such as rotary evaporator, uniform temperature, constant liquid environment. It is forbidden to store in the open air, avoid direct sunlight or rain. Do not store in corrosive or gaseous places.
2. The outer packing box shall not be disassembled during loading and unloading. Vibration and shock should be avoided during handling and placed carefully. Be careful not to damage the equipment and items inside the box when unpacking. After unpacking, a special person should be designated to keep the random data and check whether the equipment and items in the box are consistent with the packing list. Randomly damaged items and equipment must not be lost.
3. When the compressor stops and fails, the power supply should be checked first. If the power supply is OK, we need the production switch and temperature settings. If there is no abnormality, a professional electrician is required to check whether the equipment circuit is missing and whether the relay is damaged.
4. In the process of using high temperature heat transfer fluid system, operators often operate too hastily. When the machine is just running, the machine will turn to a larger temperature value. In fact, this approach often backfires. The machine is in a shutdown state, and the stirring impeller is suddenly increased to react the material, which causes the running burden of the machine. In this case, the reactor mixer is easily reversed. If there is no body reverse at that time, it will cause the mixer to deform. In addition to deformation, it will also cause the body temperature to rise rapidly and destroy the mechanical properties.
5. The user should proceed step by step during the re-use process. During the long-term operation, the temperature increase of the equipment is also a reasonable phenomenon, but because the temperature rises to the rated temperature, it will affect the reaction of the material.
Recomendações relacionadas
-
Thermal oil heating system installation and fault analysis
1272When the heat transfer oil heating system device is installed, it is necessary to pay attention to the system to avoid some faults during installation. If a fault occurs, it is necessary to understand the faults related to the heat transfer oil he...
Ver pormenores -
What are the temperature control performance of laboratory recirculating chillers
1018The laboratory recirculating chiller is atypical cooling circulator with heating function to ensure the repeatability oflaboratory results. There are water-cooled or air-cooled refrigerators, whichcan be placed in a laboratory fume hood or set ...
Ver pormenores -
A que é que devo prestar atenção ao colocar circuladores de circuito fechado de alta e baixa temperatura?
904Existem algumas diferenças no tamanho e no desempenho dos circuladores totalmente fechados de alta e baixa temperatura de diferentes fabricantes. Os utilizadores têm de prestar atenção à posição de colocação quando os colocam após a compra. Se a colocação...
Ver pormenores -
100L high and low temperature thermostat installation instructions
822The 100L high and low temperature thermostat uses coolant as the transmission medium to transfer the heat generated by other instruments or equipment that need to be cooled, and dissipate the heat to the outside of the equipment through the refrig...
Ver pormenores