Contact LNEYA sales engineer for catalog or price.
Modelo | FLTZ-203W-2T | |
Pipeline | channel 1 | channel 2 |
Gama de temperaturas | -20℃~+90℃ | -20℃~+90℃ |
Capacidade de arrefecimento | ±0.1℃(Customizable temperature control accuracy of ±0.01°C.) | |
Capacidade de aquecimento | 4kW@-10℃ | 4kW@-10℃ |
Heat conducting medium flow rate | 2kW | 2kW |
Heat conducting medium connection size | 20L/min 0.5MPa | 20L/min 0.5MPa |
Heat transfer interface | ZG3/4 | ZG3/4 |
Ambient temperature | 10~35℃ | 10~35℃ |
Ambient humidity | 30~70% | 30~70% |
Temperatura da água de arrefecimento | 15~20℃ | 15~20℃ |
Cooling water flow rate | 20L/min | 20L/min |
Peso | 400 kg | |
Dimensão cm | 50*90*160 |
Modelo | FLTZ-406W/ETCU-015W | |
Pipeline | channel 1 | channel 2 |
Gama de temperaturas | -45℃~+40℃ | +10℃~+80℃ |
Capacidade de arrefecimento | ±0.1℃(Customizable temperature control accuracy of ±0.01°C.) | |
Capacidade de aquecimento | 11kW@-20℃ 5kW@-40℃ |
13kW@+10℃ |
Heat conducting medium flow rate | 2kW | 6kW |
Heat conducting medium connection size | 17L/min 0.7MPa | 17L/min 0.7MPa |
Heat transfer interface | ZG3/4 | ZG3/4 |
Ambient temperature | 10~35℃ | 10~35℃ |
Ambient humidity | 30~70% | 30~70% |
Temperatura da água de arrefecimento | 15~20℃ | 15~20℃ |
Cooling water flow rate | 40L/min | 20L/min |
Peso | 550kg | |
Dimensão cm | 60*100*185 |
Modelo | FLTZ-203W/2T dual system | FLTZ-305W/2T dual system | FLTZ-406W/2T dual system | |||
Gama de temperaturas | -20℃~90℃ | -30℃~90℃ | -45℃~90℃ | |||
Precisão do controlo da temperatura | ±0.1℃(Customizable temperature control accuracy of ±0.01°C.) | |||||
Heat conducting medium flow rate | 15~45l/min 6bar max | |||||
Capacidade de aquecimento | 2.5kW | 2.5kW | 2.5kW | 2.5kW | 3,5 kW | 3,5 kW |
Capacidade de arrefecimento | 3kW @-15℃ | 3kW @-15℃ | 5kW @-15℃ | 5kW @-15℃ | 2.5kW @ -35℃ | 2.5kW @ -35℃ |
Volume do fluido da circulação interna | 5L | 5L | 8L | 8L | 8L | 8L |
Interface da água de arrefecimento | 50L/min at20℃ | 600L/min at20℃ | 50L/min at20℃ |
There are 2 channels with the same/different specifications in one shell;
The temperature of two fluid channel systems can be controlled separately by one host;
A power supply system achieves temperature control for two channels.
By simultaneously controlling the variable frequency compressor, variable frequency fan, and electronic expansion valve, good temperature stability can still be maintained during thermal load fluctuations.
energy are consumed;
Compressor hot gas heating within 40 degrees;
3-point temperature control
Compared to two single channel units, it reduces the overall footprint and wiring
Can reduce and share internal components.
1.Independent temperature control
Each channel of the FLTZ dual channel chiller can achieve independent temperature control. You can set different temperature ranges, cooling and heating capacities, and heat transfer medium flow rates according to application needs.
2.Compact structure
The expansion tank, condenser, cooling water system, etc. can be shared in dual channels, making your process chiller more compact and occupying a smaller area.
Por que escolher a LNEYA?
Get in touch with our Dual channel chiller experts
Não consegue encontrar um frigorífico adequado? Ou não sabe como escolher um chiller? Contacte-nos agora para obter detalhes e preços do chiller
Contactar LNEYA
Envie-nos o seu pedido e entraremos em contacto consigo no prazo de 24 horas
WeChat/Telefone
18914253067
+86 18914253067
Endereço de correio eletrónico
market@lneya.com