LNEYA’s test chamber can simulate various temperature and humidity environments, and is suitable for high and low temperature tests, wet heat tests, etc. This test chamber has a very wide temperature and humidity range and extremely high control accuracy. It can meet the national standard GB and IEC related test standards. The programmable constant temperature and humidity test chamber is used to test the heat resistance, cold resistance, dry resistance and moisture resistance of various materials. It is suitable for testing the quality of products such as electronics, electrical appliances, communications, instruments, vehicles, plastic products, metals, food, chemicals, building materials, medical treatment, and aerospace.
New energy battery test CHAMBER
Modelo | GD-9000-2-B1-KRYCH-4A15W | GD-9000-2-B1-KRYCH-475W | GD-9000-2-B1-KRYCH-4A10W | GD-1000-B1-KRYCH-475 | |||||
Gama de temperaturas | -40℃~100℃ Anticongelante |
-40℃~100℃ Câmara de ensaio |
-40℃~100℃ Anticongelante |
-40℃~100℃ Câmara de ensaio |
-40℃~100℃ Anticongelante |
-40℃~100℃ Câmara de ensaio |
-40℃~100℃ Anticongelante |
-40℃~100℃ Câmara de ensaio |
|
Controlo do fluxo de anticongelante | 1L/min~40L/min | 1L/min~25L/min | 1L/min~25L/min | 1L/min~10L/min | |||||
±0.2L/min | ±0.2L/min | ±0.2L/min | ±0.2L/min | ||||||
Pressão do anticongelante | Measure and display the inlet and outlet pressure, as well as the pressure displayed on the touch screen | ||||||||
Chamber(W*H*D) | Upper cavity cm | 220*322*120 | 220*322*120 | 220*322*120 | Single cavity:100*100*100 | ||||
Lower cavitycm | 220*322*110 | 220*322*110 | 220*322*110 | ||||||
Potência de aquecimento | 15kW | 14kW | 7,5 kW | 14kW | 10kW | 14kW | 7,5 kW | 6kW | |
Arrefecimento capacidade Anticongelante |
135℃ | 15kW | 7,5 kW | 10KW | 7,5 kW | ||||
20°℃ | 15kW | 7,5 kW | 10KW | 7,5 kW | |||||
0℃ | 15kW | 7,5 kW | 10KW | 7,5 kW | |||||
-20℃ | 10kW | 4,5 kW | 6KW | 4,5 kW | |||||
-35℃ | 4kW | 1,8kW | 2,5KW | 1,8kW | |||||
Chamber | Heating rate | 25~+100℃≥±2℃/Min (No load, average throughout the entire process) (Customizable at 5~25℃) | |||||||
Taxa de arrefecimento | 25~-40℃≥1℃/Min(No load, average throughout the entire process) (Customizable at 5~25℃) | ||||||||
Antifreeze temp control accuracy | ±0.1℃ | ||||||||
Temperature uniformity | ≤±1℃(unloaded) | ||||||||
Circulating air volume | 5000m³/h | 2500m³/h | |||||||
Cooling water 20 ℃ | 25m³/H | 20m³/H | 20m³/H | 7m³/H | |||||
Dimensão cm | 240*560*285 | 240*560*285 | 240*560*285 | 120*205*205 | |||||
Bearing | 1500kg | 1500kg | 1500kg | 120kg | |||||
Peso | 4600kg | 4200kg | 4200kg | 600kg |
Rapid temperature change test chamber
Modelo | GD-500-B-KS | GD-1000-B-KS | GD-500-C-KS | GD-500-C-KS |
Gama de temperaturas | -40℃~+150℃ | -80℃~+150℃ | ||
Inner box size (W*H*D) cm | 90*65*90 | 100*100*100 | 90*65*90 | 100*100*100 |
Heating rate | (+20~+150℃)A:5℃/min(Customizable at 15~25℃),5℃/min Adjustable nonlinearity | |||
Taxa de arrefecimento | (Carrying idler)(+20~-40℃)5℃/min | (Carrying idler)10℃/min(Customizable at 15~25℃) | ||
Temperature uniformity | ≤±1℃(unloaded) | |||
Flutuação de temperatura | ≤±0.5℃ | |||
Precisão da temperatura | ≤±0.1℃ | |||
Tamanho da janela cm | 30*45 | 45*49 | 30*45 | 45*49 |
Two-layer test chamber
Modelo | GD-300-2-B1-LX | |
Inner box size (W*H*D) cm | Upper chamber cm | 85*60*60 |
Lower chamber cm | 85*60*60 | |
Gama de temperaturas | -40℃~100℃ (-70 ℃ can be customized) | |
Heating rate | (No load) (+20 ℃~150 ℃) 1 ℃/min (Customizable at 5-25 ℃) | |
Taxa de arrefecimento | (No load) (+20 ℃~-40 ℃) 1 ℃/min (Customizable at 5-25 ℃) | |
Temperature uniformity | ≤±1℃(unloaded) | |
Flutuação de temperatura | ≤±0.5℃ | |
Precisão da temperatura | ≤±0.1℃ | |
Tamanho da janela cm | 300*450 | |
Criogénio | R404A | |
Test hole | φ100mm×1 | |
Aquecedor | Aquecimento elétrico |
Two-layer impact test chamber
Modelo | GD-200-2-B-CJ | GD-400-2-B-CJ | |
Tamanho do cesto (L * A * P) cm | 60*60*60 | 90*65*70 | |
Gama de temperaturas de impacto | Baixa temperatura | -40~0℃ | |
Alta temperatura | +60~+150℃ | ||
Taxa de aquecimento da zona de pré-aquecimento | (Sem carga) 5 ℃/min (personalizável para 10-25 ℃) | ||
Taxa de arrefecimento da zona de pré-arrefecimento | (Sem carga) 2 ℃/min (personalizável para 5-25 ℃) | ||
Área de pré-arrefecimento Gama de pré-arrefecimento | -10℃~-55℃ | ||
Área de pré-aquecimento Gama de pré-aquecimento | +60~+180℃ | ||
Tempo de permanência | ≥30min | ||
Tempo de recuperação | ≤ 5 minutos para recuperar com uma precisão de ± 2 ℃ | ||
Flutuação de temperatura | ≤1℃ | ||
Tempo de permanência | ≥30min | ||
Tempo de conversão do cesto | ≤10S | ||
Tamanho da janela cm | 300*450 | ||
Criogénio | R404A/R23 | ||
Aquecedor | Aquecimento elétrico |
Left & right multi-layer test chamber
Modelo | GD-518-2-C-DC | |
nside dimensions (W*H*D) |
Left cavity cm | 60*124.5*65 |
Right cavity cm | 60*124.5*65 | |
Gama de temperaturas | -80℃~150℃ | |
Heating rate | (No load) -40 ℃ →+125 ℃ 1 ℃/min (customizable for 5-25 ℃) | |
Taxa de arrefecimento | (No load) 125 ℃ → -40 ℃ 1 ℃/min (customizable for 5-25 ℃) | |
Temperature uniformity | ≤±1℃(unloaded) | |
Precisão da temperatura | ≤±0.1℃ | |
Criogénio | R404A/R23 | |
Aquecedor | Aquecimento elétrico |
Walk-in test chamber
Modelo | GD-8000-C-BR | ||
Inner box capacity | 8000L | ||
Inner box size (W*H*D) cm | 200*200*200 | ||
Outer box size (W*H*D) cm | 224*242*350 | ||
Gama de temperaturas | -80~+150℃ | ||
Temperature uniformity | ≤±1℃(unloaded) | ||
Flutuação de temperatura | ≤1℃ | ||
Precisão da temperatura | ≤±0.1℃ | ||
Heating rate | (No load) 1 ℃/min adjustable nonlinearity; (Customizable at 5-25 ℃) | ||
Taxa de arrefecimento | (No load) 1 ℃/min adjustable nonlinearity; (Customizable at 5-25 ℃) | ||
Criogénio | R404A/R23 | ||
Test hole | φ100mm×1 | ||
Aquecedor | Aquecimento elétrico | ||
Tamanho da janela cm | 450*490(2 pieces) |
Constant temperature & humidity test chamber
Modelo | GD-500-C-WS | GD-1000-C-WS | |
Inner box size (W*H*D)cm | 90*90*65 | 100*100*100 | |
Gama de temperaturas | -80~+150℃ | ||
Heating rate | (No load) (+20~150 ℃) 2 ℃/min (Customizable at 5~25 ℃) | ||
Taxa de arrefecimento | (No load) (+20~-70 ℃) 1 ℃/min (Customizable at 5-25 ℃) | ||
Temperature uniformity | ≤± 1 ℃ (unloaded) | ||
Humidity fluctuation | ±3.0%RH(>75%RH);±5.0%RH(≤75%RH) | ||
Flutuação de temperatura | ≤±1℃ | ||
Humidity accuracy | ≤±2.0%RH | ||
Precisão da temperatura | ≤±0.1℃ | ||
Material da caixa interior | Aço inoxidável SUS304 | ||
Material da caixa exterior | Chapa de aço laminada a frio + revestimento por pulverização | ||
Material de isolamento | Fibra de vidro, algodão e poliuretano | ||
Tamanho da janela cm | 30*45 | 45*49 | |
Criogénio | R404A/R23 | ||
Test hole | φ100mm×1 | ||
Aquecedor | Aquecimento elétrico |