SR & ZLF series TCU Reactor Cooling Heating Temperature Control System
APLICAÇÕES
TCU temperature control system uses existing thermal energy (such as steam, cooling water and ultra-low temperature liquid - the "primary system") infrastructure to integrate into a single fluid system or secondary loop used to control the temperature of process equipment. It can achieve dynamic temperature control from -120℃ to 300℃.
Caraterísticas do produto
Parâmetros do produto
Modelo | ZLF-35N ZLF-35NS ZLF-35NH ZLF-35NSH |
ZLF-50N ZLF-50NS ZLF-50NH ZLF-50NSH |
ZLF-80N ZLF-80NS ZLF-80NH ZLF-80NSH |
ZLF-125N ZLF-125NS ZLF-125NH ZLF-125NSH |
ZLF-200N ZLF-200NS ZLF-200NH ZLF-200NSH |
Gama de temperaturas | -45-250 (the max Temp is determined by the heat and cold source supplied by the user)-40-135(The maximum temperature range can be operated by using glycol water formula solution) | ||||
ZLF-N | A fonte principal de frio/ou a fonte principal de calor é utilizada para regular o fluxo do sistema através do sistema de regulação proporcional e controlar o calor do aperto do tanque de reação, e um conjunto de permutador de calor para aquecimento ou arrefecimento é controlado ou arrefecido. | ||||
ZLF-NS | Besides ZLF-N function, add one set heater used to reduce high temp | ||||
ZLF-NH | Besides ZLF-N function, add electrical heating function | ||||
ZLF-NSH | Além da função ZLF-N, adicione um conjunto de aquecedor usado para reduzir a alta temperatura e a função de aquecimento elétrico | ||||
Área do permutador de calor | 3.5㎡ | 5㎡ | 8㎡ | 12.5㎡ | 20㎡ |
Electric heatingfunction H | 25kW | 35kW | 50kW | 65kW | 80kW |
With 'H' has heating function | |||||
Modo de controlo | Feed forward PiD + Our special dynamic control calculation, LNEYA PLC controller | ||||
Protocolo de comunicação | MODBUS RTU protocol, RS485 interface, optional Ethemet interface/R232 interface | ||||
Seleção do controlo da temperatura | Controlo da temperatura do processo | ||||
Feedback da temperatura | The temp of three points: the inlet and outet of heat-conducing medium, material in reactor(External temp), PT100 sensor | ||||
Process temp feedback | Feedback do processo de matéria-prima: PT100 ou 4 ~ 20mA ou comunicação fornecida | ||||
Precisão da temperatura | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ |
Bomba de circulação | 150L/min 2,5BAR | 200L/min 2,5BAR | 400L/min 2,5BAR | 500L/min 2,5BAR | 750L/min 2,5BAR |
Entrada e visualização | Ecrã tátil a cores de 7 polegadas, visualização de gráficos de temperatura | ||||
Proteção de segurança | Self-diagnosis funcion;freezer overoad protecion; high pressure switch;, overload relay; themal protection device; high temp Protection and temp faut protecion | ||||
Executar peça de válvula | Proportional control valve control signal 4-20mA | ||||
Material da caixa | SUS304 | ||||
Tamanho da ligação | DN40 | DN40 | DN50 | DN65 | DN80 |
Dimensão cm | 150*120*185 | 180*120*210 | 180*120*210 | 225*120*240 | 225*120*240 |
Power AC380V 50HZ | 2,3kW | 3,5 kW | 4,5 kW | 8kW | 10.5kW |
With H power AC380V 50HZ | 27.3kW | 38.5kW | 54.5kW | 73kW | 90.5kW |
Shell materia | Chapas laminadas a frio (REL7035) |
Modelo | SR-35N SR-35NS SR-35NH SR-35NSH |
SR-50N SR-50NS SR-50NH SR-50NSH |
SR-80N SR-80NS SR-80NH SR-80NSH |
SR-125N SR-125NS SR-125NH SR-125NSH |
SR-200N SR-200NS SR-200NH SR-200NSH |
Gama de temperaturas | -120~250 (the max. Temp is determined by the heat and cold source supplied by the user)-40~135(The maximum temperature range can be operated by using glycol water formula solution) | ||||
SR-N | A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansion tank |
||||
SR-NS | Besides SR- N function, add one set heater used to reduce high temp | ||||
SR-NH | Besides SR- N function, add electrical heating function | ||||
SR-NSH | Besides SR- N function, add one set heater used to reduce high temp and electrical heating function | ||||
Depósito de expansão | 100L | 200L | 280L | 390L | 500L |
Área do permutador de calor | 3.5㎡ | 5㎡ | 8㎡ | 12.5㎡ | 20㎡ |
Electric heatingfunction H | 25kW | 35kW | 50kW | 65kW | 80kW |
With 'H' has heating function | |||||
Modo de controlo | Feed forward PiD + Our special dynamic control calculation, LNEYA PLC controller | ||||
Protocolo de comunicação | MODBUS RTU protocol, RS485 interface, optional Ethemet interface/R232 interface | ||||
Seleção do controlo da temperatura | Controlo da temperatura do processo | ||||
Feedback da temperatura | The temp of three points: the inlet and outet of heat-conducing medium, material in reactor(External temp), PT100 sensor | ||||
Process temp feedback | Feedback do processo de matéria-prima: PT100 ou 4 ~ 20mA ou comunicação fornecida | ||||
Precisão da temperatura | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ |
Bomba de circulação | 200L/min 2,5BAR | 250L/min 2,5BAR | 400L/min 2,5BAR | 500L/min 2,5BAR | 750L/min 2,5BAR |
Entrada e visualização | Ecrã tátil a cores de 7 polegadas, visualização de gráficos de temperatura | ||||
Proteção de segurança | Self-diagnosis funcion;freezer overoad protecion; high pressure switch;, overload relay; themal protection device; high temp Protection and temp faut protecion | ||||
Executar peça de válvula | Proportional control valve control signal 4-20mA | ||||
Material da caixa | SUS304 | ||||
Tamanho da ligação | DN40 | DN40 | DN50 | DN65 | DN80 |
Dimensão cm | 150*120*185 | 180*140*240 | 180*140*240 | 220*180*265 | 220*180*265 |
Power AC380V 50HZ | 2,3kW | 3,5 kW | 4,5 kW | 8kW | 10.5kW |
With H power AC380V 50HZ | 27.3kW | 38.5kW | 54.5kW | 73kW | 90.5kW |
Shell materia | Chapas laminadas a frio (REL7035) |
PRINCÍPIO DE FUNCIONAMENTO
(Control the temperature of the reactor material)
- The method of changing the control set value can respond to the system lag in the process as quickly as possible and obtain a smaller system overshoot. The control consists of two sets of PID control loops, which are called: main loop and slave loop. The control output of the main loop is used as the set value of the slave loop. By controlling the temperature change gradient in this way, the temperature control accuracy of the system is guaranteed.
- The specially designed hysteresis predictor generates a dynamic signal yc(t) instead of the process variable y(t) as a feedback signal. Generate an e(t) signal for the controller, so that the controller predicts that the control action has no large lag.

FOR REACTOR SYSTEMS TEMPERATURE CONTROL
One host controls 5~60 different reactors
Non-contact temperature control system in the jacket of the reaction vessel
Each reactor is independently controlled and does not affect each other