Pesquisar toda a estação


Centro de notícias

KRY -40℃~+100℃ (1to6)

KRYO 0℃~160℃

Oil Cooling Chiller
  • Precisão da temperatura±0.3℃
  • Flow Accuracy±0.2L/min
  • Capacidade de arrefecimento12kW~38kW
  • Heating Capacity15kW~38kW
  • Saída do caudal1~40 L/min
  • CoolantOil

The object under test is connected to a test platform adapter
The component is cooled and heated by ethylene glycol water solution
-40’C~100°C (expandable to 150°C)

 

KRYO SERIES A15W A25W A38W A15W2S A25W2S A38W2S
Gama de temperaturas 0℃ ~ +160℃ Different viscosity oils have different temperature ranges
Controlo da temperatura accuracy ±0.3℃
Reação à temperatura PT100
Controlo do fluxo 2L/min~20L/min, one in and one out, in and out control linkage 2L/min~15L/min Two outputs, one input Flow control linkage
Flow accuracy ±0.2L/min
Controlo da pressão 0.2bar~2.5bar
Heating capacity kW 15 25 38 15 25 38
Cooling capacity kW 125℃ 15 25 38 15 25 38
20℃ 12 20 30 12 20 30
Compressor Emerson Copeland Scroll Flexible Compressor/Japanese Scroll Flexible Compressor
Método de estrangulamento Válvula de expansão eletrónica
Evaporador Permutador de calor de placas
Bomba de circulação Gear Pumps
Flow regulation Inverter vector control
Entrada, ecrã 7-inch color touch screen/PLC controller
Communications CAN communication
Refrigerante R410A
Coolant Oil
Liquid inlet and outlet G3/4
Água de arrefecimento @20℃ 3000L/H 4200L/H 6200L/H 3000L/H 4200L/H 6200L/H
Ligação da água de arrefecimento G3/4 G3/4 G1 G3/4 G3/4 G1  
fonte de alimentação 380V 50HZ three-phase five-wire
Disjuntor 50A 80A 125A 50A 80A 125A
External tooling External oil return tooling size 600×850×600
If the external oil return fixture is selected, the fixture needs to be installed under the test motor.
Request a quotation about oil cooling chiller
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

recomendar produtos

  • KRY -40℃~+100℃ (1to6)"      /&gt;<figcaption><span>The components are cooled and heated internally through ethylene glycol aqueous solution for testing -40 ° C~100 ° C (expandable to 150 ° C) For the power battery charging management, the precision …</span></figcaption></figure></a></div><div class= KRY -40℃~+100℃ (1to6)

    The components are cooled and heated internally through ethylene glycol aqueous solution for testing -40 ° C~100 ° C (expandable to 150 ° C) For the power battery charging management, the precision …

  • KRY -40℃~+100℃ (1to1)"      /&gt;<figcaption><span>Refrigeration, heating, temperature control, flow control Connect the tested object to a testing platform adapterThe components are cooled and heated internally through ethylene glycol aqueous solution for testing. …</span></figcaption></figure></a></div><div class= KRY -40℃~+100℃ (1to1)

    Refrigeration, heating, temperature control, flow control Connect the tested object to a testing platform adapterThe components are cooled and heated internally through ethylene glycol aqueous solution for testing. …

  • KRY -40℃~+100℃ (1to2)"      /&gt;<figcaption><span>Temperature range is -40℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. Theequipment can control the flow and pressure independently while c…</span></figcaption></figure></a></div><div class= KRY -40℃~+100℃ (1to2)

    Temperature range is -40℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. Theequipment can control the flow and pressure independently while c…

  • KRY -40℃~+100℃ (1to3)"      /&gt;<figcaption><span>Dimension(A) cm Temperature range is -40℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. Theequipment can control the flow and…</span></figcaption></figure></a></div><div class= KRY -40℃~+100℃ (1to3)

    Dimension(A) cm Temperature range is -40℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. Theequipment can control the flow and…

carregando...

已经是到最后一篇内容了!